Model |
Rated Capacity (t/h) |
Rated Pressure (Mpa) |
Rated Temperature (C) |
Thermal Efficiency (%) |
Exhaust gas temperature(ºC) |
Maximum transport weight of boiler(t) |
Maximum transport size of boiler( mm) |
Fuel Consumption
|
|
||||||||
|
|
|
|
|
|
|
|
Light oil (Kg/h)
|
Natural gas (Nm³/h)
|
||||||||
WNS1
|
1
|
0.7/ 1.0/ 1.25 |
170/ 184/ 194 |
>98
|
≤60
|
6.8
|
3400× 1700×2100
|
61.5
|
70.4
|
||||||||
WNS1.5
|
1.5
|
|
|
>98
|
≤60
|
7.7
|
3800× 1900×2400
|
93.75
|
107.1
|
||||||||
WNS2
|
2
|
1.0/ 1.25/ 1.6 |
184/ 194/204 |
>98
|
≤60
|
8.2
|
4300× 1900×2300
|
125
|
142.8
|
||||||||
WNS3
|
3
|
|
|
>98
|
≤60
|
9.9
|
3900×2100×2500
|
187.5
|
214.2
|
||||||||
WNS4
|
4
|
|
|
>98
|
≤60
|
12.7
|
4700×2200×2600
|
250
|
285.6
|
||||||||
WNS5 |
5 |
|
|
>98 |
≤60 |
14.2 |
5200×2300×2700 |
312.5 |
357 |
||||||||
WNS6 |
6 |
|
|
>98 |
≤60 |
17.5 |
5660×2400×2800 |
375 |
428.4 |
||||||||
WNS8 |
8 |
1.25/ 1.6/2.5 |
194/204/225 |
>98 |
≤60 |
21.3 |
5900×2500×3000 |
500 |
571.2 |
||||||||
WNS10 |
10 |
|
|
>98 |
≤60 |
22 |
6600×2700×3200 |
625 |
714 |
||||||||
WNS12
|
12
|
|
|
>98
|
≤60
|
27.2
|
7000×3000×330
|
750
|
856.8
|
||||||||
WNS15 |
15 |
|
|
>98 |
≤60 |
35.5 |
7500×3400×3600 |
937.5 |
1071 |
||||||||
WNS20 |
20 |
|
|
>98 |
≤60 |
45 |
7800×3700×4200 |
1250 |
1428 |
||||||||
|
Note: 1、Fuel type:Light diesel oil/Heavy oil/Natural gas/Liquefied gas/City gas
2 、Parameter is for reference only, we can design the boilers based on customers’ needs. |
|
|
|
|
|
|
|
|