63953f7436a73c7da61711d2768f6d35.jpg
9510a0783fe73625895cf0094020615f.jpg
70f2c944b6c9333b837addd6a57f9da4.jpg
3b76b7d129ff399ebd5acc65d3b96247.jpg
NaN / 0

Overhead 30mm 50mm 75mm AAC AAAC ACSR HDA SCA Bare Aluminum Conductor Wire Price

Get Latest Price
US$ 0.1
≥100 Meters

Quick Details

Insulation Material:
Xlpe
Application:
Overhead
Conductor Material:
Aluminum
Jacket:
None
Product Details
Overhead 30mm 50mm 75mm AAC AAAC ACSR HDA SCA Bare Aluminum Conductor Wire Price
Product Paramenters
Overhead 30mm 50mm 75mm AAC AAAC ACSR HDA SCA Bare Aluminum Conductor Wire Price
Overhead 30mm 50mm 75mm AAC AAAC ACSR HDA SCA Bare Aluminum Conductor Wire Price
Specifications

Rated Voltage: 0.6/1KV, 11KV, 33KV
Construction: Phase conductor: aluminum stranded(AAC)
Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)
Insulation: XLPE or PE
Application:
Primarily used for overhead service application such as street lighting,outdoor lighting,and temporary service for construction, To be used at voltage of 600V to 2200V phase-to-phase or less at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross liked polyethylene insulated conductors.

1 . Standard
Duplex service drop cable meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for electrical purposes
B-231 Aluminum conductors, Concentric-lay-Stranded
B-232 Aluminum conductors, Concentric-lay-Stranded, Coated Steel, 6201-T81 Aluminum
Service Drop cable meets or exceeds all applicable requirements of ICEA S-76-474


2.Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.


3. Product structure size and reference data
SPEC mm2
conductor structure
Phase
Neutral(Bare ACSR)
insulationmaterial
insulation
Thickness
(mm)
Approx.
Overall
Diameter
(mm)
Approx.
Weight
(kg/km)

(Compacted AL)
(No./mm)
Aluminium
(No./mm)
Steel
(No./mm)
material
Thickness
Diameter
Weight
(No./mm)
(No./mm)
(No./mm)
(mm)
(mm)
(kg/km)
1x16+1x16
7/1.72
6/1.72
1/1.72
XLPE
1.2
12.5
121.9
1x25+1x25
7/2.15
6/2.15
1/2.15
1.2
14.9
182.2
1x35+1x35
7/2.54
6/2.54
1/2.54
1.4
17.5
254.7
1x50+1x50
7/2.92
6/2.92
1/2.92
1.4
20.1
333.9
1x70+1x70
19/2.15
12/2.15
17/2.15
1.4
23.6
382.2
1x95+1x95
19/2.54
12/5.24
17/5.24
1.6
27.6
528.2
2x16+1x16
7/1.72
6/1.72
1/1.72
(HDPE)
1.2
14.2
187.6
2x25+1x25
7/2.15
6/2.15
1/2.15
1.2
16.7
273.8
2x35+1x35
7/2.54
6/2.54
1/2.54
1.4
19.7
386.9
2x50+1x50
7/2.92
6/2.92
1/2.92
1.4
22.5
506
2x70+1x70
19/2.15
12/2.15
7/2.15
1.4
26.1
617.2
2x95+1x95
19/2.54
12/5.24
7/5.24
1.6
30.5
850.9
3x16+1x16
7/1.72
6/1.72
1/1.72
1.2
16.3
253.3
3x25+1x25
7/2.15
6/2.15
1/2.15
1.2
19.1
371.9
3x35+1x35
7/2.54
6/2.54
1/2.54
1.4
22.5
519.1
3x50+1x50
7/2.92
6/2.92
1/2.92
1.4
25.7
678.1
3x70+1x70
19/2.15
12/2.15
7/2.15
1.4
29.7
1024.3
2x95+1x95
19/2.54
12/2.54
7/2.54
1.6
34.6
Code Name
Phase Conductor
Bare Neutral Messenger
Weight Per 1000ft (lbs)
Ampacity(amps)
Code Name
Size AWG
Stranding
Insulation Thickness(mls)
Size AWG
Stranding
Insulation Thickness(mls)
XLPE
Poly
XLPE
6201 ALLOY NEUTRAL-MESSENGER
Minex
6
Solid
45
6
7
1,110
106.6
102.9
85
Hippa
6
7
45
6
7
1,110
113.2
105.7
85
Prawn
4
Solid
45
4
7
1,760
158.4
154.1
115
Barnacles
4
7
45
4
7
1,760
168.3
158.2
115
Shrimp
2
7
45
2
7
2,800
253.7
239.7
150
Gammarus
1/0
7
60
1/0
7
4,460
411.7
386
205
Leda
1/0
19
60
1/0
7
4,460
402.7
386
205
Dungenese
2/0
7
60
2/0
7
5,390
506.8
476.3
235
Cyclops
2/0
19
60
2/0
7
5,390
495.3
476.3
235
Dlustra
3/0
19
60
3/0
7
6,790
611.4
589.1
275
Lepas
4/0
19
60
4/0
7
8,560
757.1
730.5
315
Overhead 30mm 50mm 75mm AAC AAAC ACSR HDA SCA Bare Aluminum Conductor Wire Price