121a3ae505a6393b97295a876bdd204e.png
48231a9c127a3ba296b181c36566639d.png
a3f2da2754353faf849d23dac27a8b81.png
cbd77ceea74f35d9bcb4e061c459013a.png
NaN / 0

JX AUTO CNC portable glass edge acrylic flame gas gun polishing machine electric polisher

Get Latest Price
US$ 60
≥50 Sets

Quick Details

Voltage:
220V/50HZ
Rated Voltage:
200V
Rated Input Power:
300W
Grade:
flame polishing polisher machine
Product Details
JX AUTO CNC portable glass edge acrylic flame gas gun polishing machine electric polisher
Products Description
Gas acrylic flame polishing machine
JX AUTO CNC portable glass edge acrylic flame gas gun polishing machine electric polisher
Attention :
Electrolyte: It must be filled for the first time. Strong alkaline 15-20% concentration.
Consumed fuel: water (distilled water, pure water, cold water, tap water)
Filter: Alcohol or distilled water with a purity above 95
Working environment: 0 °C ~ 50 °C, well-ventilated or air-conditioned environment
Product Paramenters
Gas acrylic flame polishing machine Machine parameter :
Model
JX160
JX180
JX260
Voltage
AC200-240V/1.2A
AC200-240V/1.5A
AC200-240V/2.5A
Atmospheric pressure
0.13-0.15Mpa
0.13-0.15Mpa
0.13-0.15Mpa
Maximum gas production
75L/H
95L/H
150L/H
Maximum gas consumption
25mL/H
30mL/H
50mL/H
Water capacity
1.0L
1.0L
3.8L
Electrolyte concentration
15%
15%
15%
Max power
Max power
500W
800W
Packing size
450*280*360mm^3
480*280*360mm^3
520*300*540mm^3
Weight
7KG
8KG
14KG
Spare list
Model
JX160
JX180
JX260
Fire Gun
1 set
1 set
2 set
electrolytic cylinders
1 set
1 set
2 set
Electrolytic powder
1 set
1 set
2 set
PVC pipe
1 set
1 set
14set
funnel
1 set
1 set
1 set
Tempering valve
-
-
1 set
Tee connector
-
-
1 set
JX AUTO CNC portable glass edge acrylic flame gas gun polishing machine electric polisher
Products Description
USE instruction :
1. Pour 0.25kg of special electrolyzed powder into the alkali-resistant dissolver, add a small amount of distilled water
(completely dissolve the electrolyzed powder), stir it for a little while, and let it cool for about 20 minutes. Connect the hose
and flame gun, connect the air outlet, select the nozzle type according to the thickness of the burr

2. Unscrew and add the solution nut. Slowly fill to a level below the "high" level (never exceed 90 degrees) and tighten the nut.

3. loosen the alcohol tank, slowly add alcohol (not more than 50%), tighten the alcohol tank.

4. connect the power to start, the power indicator light, fan switch, gas outlet gas sense, pressure gauges have instructions,that all is normal.

5, open the spray gun regulating valve, the first use of attention to 5 seconds after the open flame, flame straight or inclined to the flash, keep the appropriate distance, evenly scan it.

6. Add water in a timely manner. If it is found that the liquid level indication has dropped significantly, it is necessary to add
water in a timely manner (without adding electrolytic powder).

7. Electrolyte powder preparations are properly filled when the current is significantly reduced
.
After service