Why choose us:
1. The biggest ATS manufacture in China - more than 300 companys make OEM,ODM order from us
2. Exporting experience - We have export to all over the world for more than 7 years.
3. Annual sales- The total Annual sales is about USD17,000,000.
4. Certification - We have passed ISO9001:2008 Quality Management System and CCC, CE
PC Class Double Throw 100amp ATS for Generators YES1-125NA
1) Rated current : 40-125A
2) Pole number: 2p, 3p, 4p
3) Rated working voltage: AC 240V/400V(110/220/380/660VAC available), 50/60Hz
4)EMC /life enduring/temperature rising /character and comprehensive testing equipments are configurated to guanrante the product quality.
5)Serve district:hospital,shoping mall,bank,fire control,ppostal communication,urban rail transportion, high-rise buildings,industrial assembly line,television station,chemical industry,metallurge industry,military and so on places
Quality Control
1)standards
A)GB/T14048 supercript<high-rise buildings fire norms>,<Architectural Design firenorms>,<Emergency Lighting Design Guide>,<Civil Electrical Design Specification>
B) IEC60947-1/GB/T4048.1< low voltage switchgear and control equipment general>IEC60947-3/GBI4048.3< low voltage switchgear and control equipment ,low voltage switches, disconnector, Switches and electrical fuse combination>
IEC60947-6/GBI14048.11 <low voltage switchgear and control equipment multifunctional transfer switch equipment>
2)All the components are aged and selected strictly, the finished products are continuously aging for 24hours at high temperature condition;
3)EMC /life enduring/temperature rising /character and comprehensive testing equipments are configured to meet relative test and guarantee the product quality.
4)During the production process ,ISO9001 production and management system is strictly carried;
5)CE,CCC are certified.
Features:
1) Provided with such protective functions as checking two sources of voltage atthe same time, protection when any one phase or one phase above experiences under- or over-voltage, guide phase;
2) When two sources have abnormal or faulty tripping (overload, short circuit), thecontroller won't send out the order to realize the protective function of reopeningand closing;
3) Four working modes: automatic control, common source (power supply I), standbypower supply (power supply II), breaking electricity (re-tripping);
4) When the working mode is in the automatic control state, it has two self-throw no self-recover, self-throw, and self-recover functions
a) Self-throw non-self recover: when the device enters the working state, power supply automatically throws into supplying electricity; when power supply I has an abnormity, it will automatically transfer to power supply II; when power supply I recovers, it doesn't transfer until power supply II has an abnormity, then it will automatically transfer to power supply;
b) Self-throw and self-recover: when the device enters the working state, the common source throws into supplying electricity; when power supply has an abnormity,it will automatically transfer to standby power supply; when common power supply recovers, it will automatically recover common power supply; but when the standby power supply has an abnormity, the controller will emit an alarm sound
Parameters
rated current(A) | 40/63/80/100/125 |
working current(A) | 3.5 |
rated tolerance current in short time(KA) | 5 |
mechanical life (times) | 8000 |
citing mode.
1 |