Ambient temperature
|
-40℃~50℃
|
Relative humidity
|
0~95%
|
Atmospheric pressure
|
80 kPa ~110kPa
|
Working voltage
|
AC220V 50/60HZ
|
Power consumption of the whole machine
|
15W
|
Output mode and quantity
|
2×SPDT(4-20mA)
|
Contact rating
|
AC250V 3A DC30V 3A
|
Detection range
|
10~9999 R/min
|
Optimum detection distance of sensor head
|
10mm
|
Alarm threshold
|
Alarm 1:Speed reduced by 10%
Alarm 2:Speed reduced by 50% |
Start delay
|
10 S
|
Protection level
|
IP67
|
Display mode
|
Double-row 8-bit LED digital tube
|
Analog mode
|
4~20 mA
|
Accuracy of analogue quantity
|
0.1%
|
Analog load capacity
|
300 Ω
|
Communication mode
|
RS485
|