EVI Low temp. Industrial air source Heater Heat pump low cost Juteng Copeland compressor heating, hot water apparatus
EVI Air Source heat pumps transfer heat from the ambient air to water , providing high-temperature hot water up to 60 °C.
The unique Low ambient -temperature heat pump is widely used for house warming. With innovative & advanced technology, the direct-heating heat pump can operate very well at - 25 ℃ ambient temperature with high output temperatures up to 60 ℃, which ensures the compatibility with normal sized radiator based systems without supplementation.
Compared with traditional oil/LPG boilers, high-temperature heat pump produces up to 50% less CO 2 whilst saves 80% running cost.
O ur heat pumps are not only highly efficient, but also easy and safe to operate.
Working principle:
C ompressor absorbs low temperature and low pressure refrigerant gas from the evaporator, then refrigerant compressed to high temperature and high pressure gas . The h igh temperature and high pressure gas goes into the condenser through fan to e xchange heat with the air , and condensed into cryogenic liquid in the condenser and give off a lot of heat .
The air absorbs the heat and the temperature increasing. High pressure and low temperature liquid is throttled and depressurized through the expansion valve, absorbs heat from the surrounding air and volatilize into low pressure gas by fan in the evaporator, being compressed in the compressor, this repeated cycle, so as to continuously rise the water temperature.
PRODUCTION PROCESS of HEAT PUMP
1. Base plates go online
2. Install compressors, condensers and evaporators
3. Assemble and weld copper pipes
4. Recharged with Nitrogen
5. Water-inspection (Check if exist in air leakage)
6. Discharge Nitrogen
7. Vacuum air-removed
8. Add refrigerant
9. Halogen inspection
10. Fix fan component
11. Install electrical control
12. Security checks (Insulation, Ground connection, Dielectric Strength test, Leakage)
13. Run commodity inspection (The noise of components and parts, Function, Timing, shutdown, current, Difference in temperature)
14. Stick nameplate and connection diagram
15. Document attached (Product Manuals, instructions)
16. Final inspection (Appearance parts)
17. Packing
18. Tape-out
Parameter
MODEL | JTT-10L | JTT-17II/L | |
Hot water capacity | kW | 10.30 | 17.80 |
COP in Hot Water (A9/A19) Refer row 40 | 4.44 | 4.43 | |
Rise in water Temp required | °C | 40 °C | |
Hot water output under recirculations | L/h | 295 Liters/Hour | 510 Liters/Hour |
Rated outlet water Temp. | °C | 55 °C | |
Max outlet water Temp. | °C | 60 °C | |
Space Heating capacity water (in/out):35℃/40℃ | kW | 8.2 | 14.6 |
COP Space Heating (A15/A19) Refer row 54 | 3.53 | 3.63 | |
Space Heating capacity water (in/out):40℃/45℃ | kW | 8.2 | 14.6 |
COP Space Heating (A17/A19) Refer row 55 | 3.53 | 3.63 | |
Rated power input | Kwh | 2.32 | 4.02 |
Rated current | A | 11.10 | 7.63 |
Power supply | V/Hz/Ph | 220~240/1/50 | 380~415/3/50 |
Compressor type | Copeland Scroll | ||
Number of Compressors | pc | 1 | 1 |
Heat exchanger type | High efficiency tube intube heat exchanger | ||
Throttling device | Emerson thermal expansion valve | ||
Condensor Fan type | Low noise high effciency axial type | ||
Condensor Fan discharging | Vertical | ||
Condensor Fan quantity | 1 | 1 | |
Condensor Fan input power | W | 70 | 250 |
Condensor Fan speed | RPM | 850 | 880 |
Ambient temperature | ℃ | (-25℃~+43℃) | |
Refrigerant | R407C/R417A | ||
Noise in 1 meter distance | dB | 59 | 62 |
Water pipe size | inch | R1 | R1 |
PLC Controller | Yes Digital LCD Controller | ||
Cabinet | GI powder coated steel / Stainless Steel @ extra cost | ||
Product dimensions | mm | 710/ 710/ 795 | 810/ 810/ 995 |
Product Net weight | kg | 107 | 129 |
Package dimensions | mm | 810/ 810/ 980 | 920/ 920/ 1080 |
Shipping Weight | KG | 115 | 148 |
Test: 1.Above datas were checked according to GB/T18430.2-2008,GB/T21362-2008,GB/4706.1,GB/4706.32,GB/4706.12,GB/4343.1,GB25127.2-2010 GB/17625.1 working condition. 2.Working condition cooling mode water flow 0.172m³/(hkW),temperature of chilled water outlet 12℃/7℃,ambient temperature 35℃/24℃.3,Working condition cooling mode water flow 0.172m³/(hkW),temperature of hotwater outlet 36℃/41℃,ambient temperature -12℃
Mr Patrick Huang
Cell/WhatsApp: +86 139 2545 8470