30 kva 30kw high frequency three phase input and output double conversion pure sine wave online ups

Get Latest Price
US$ 2700
≥1 Pieces
US$ 2600
≥10 Pieces
US$ 2450
≥30 Pieces
US$ 2200
≥50 Pieces

Quick Details

Warranty:
1year
Place of Origin:
Guangdong, China
Brand Name:
BAYKEE
Model Number:
HTT-30KVA
Product Details
Product Description


H TT Series Single phase, Three phase high frequency online UPS


HTT series high frequency online 3/3 phase UPS adopt double conversion true online architectural design, is the best architectural design which can solve all power supply problems. The power factor of HTT series ups range from 0.9 to 1. The whole system efficiency reaches to 98%. Small and medium-sized data centers, network management center, computer rooms for enterprises, control center for manufacture,transportation, energy source etc. field, And for industrial precision production and test equipment(like SMT, AI equipment).
Main Features
1. DSP control, double conversion true online three phase input three phase output UPS
2. Through filter, PFC, and convert AC into DC, and then DC is converted into AC output by inverter.
3. Adopt similar to modular design; integrate the every phase power parts into the same PCB boards. But not whole module design.
4. Advanced adaptive feed forward offset control, low harmonic distortion
5. THDi<1%
6. Input power factor: 0.99@10% load
7. Efficiency: 95%
8. Compact design, high space use
9. In front of the operation design, ease of maintenance and replacement
10. Can set input/output single phase/three phase
11. Compatible with various types of loads
12. Can 4pcs in parallel
13. With kinds of communication interface
14. More than 60% recyclable material
15. Display the remaining discharge time
16. Digital LCD display, beautiful and easy to operate
17. Compatible with many languages
18. This series max. power is 200kVA

30 kva 30kw high frequency three phase input and output  double conversion  pure sine wave online ups
30 kva 30kw high frequency three phase input and output  double conversion  pure sine wave online ups
30 kva 30kw high frequency three phase input and output  double conversion  pure sine wave online ups
Specification
HTT Series Specification
Model
HTT-10kS
HTT-10kH
HTT-15kS
HTT-15kH
HTT-20kS
HTT-20kH
Capacity
10kVA / 8kW
15kVA / 12kW
20kVA / 16kW
Input




Voltage range
Low line loss
110 VAC(Ph-N) ± 3 % at 50% load
176 VAC(Ph-N) ± 3 % at 100% load
Low line comeback
Low line loss voltage + 10V
High line loss
300 VAC(L-N) ± 3 % at 50% load
276 VAC(L-N) ± 3 % at 100% load
High line comeback
High line loss voltage - 10V
Frequency range
46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system
Phase
Three phase with neutral
Power factor
≧ 0.99 at 100% load
Output
Phase
Three phase with neutral
Output voltage
208/220/230/240VAC(Ph-N)
AC voltage regulation
± 1%
Frequency range (Synchronized range)
46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system
Frequency range (Batty. mode)
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz



Overload

AC mode
100%~110%: 10min
110%~130%: 1min
>130% : 1sec

Battery mode
100%~110%: 30sec
110%~130%: 10sec
>130% : 1sec
Current crest ratio
3:1 max
Harmonic distortion
≦ 2 % @ 100%linear load; ≦ 5 % @ 100% Non-linear load


Transfer time
Line To Battery
0 ms
Inverter To Bypass
0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
Inverter To ECO
<10 ms
Efficiency
AC mode
> 89%
>89%
>89%
Battery mode
> 86%
>88%
>87%
Battery
Type
12 V / 9 Ah
12 V / 9 Ah
12 V / 9 Ah



Standard model
Numbers
20(18-20 adjustable)
2 x 20(18-20
2 x 20(18-20
Recharge time
9 hours recover to 90% capacity
Charging current
1.0 A ± 10% (max.)
2.0 A ± 10% (max.)
2.0 A ± 10% (max.)
Charging voltage
273 VDC ± 1%


Long-run model
Type
Depending on applications
Numbers
18 - 20
Charging current
4.0 A ± 10% (max.)
4.0 A ± 10% (max.)
4.0 A ± 10% (max.)
Charging voltage
273 VDC ± 1%
Physical


Outline
Dimension, D X W X H mm
815X250 X826
592X250 X826
815X250 X826
592X250 X826
815X250 X826
592X250 X826
Outline
Net weight (kg)
109
38
164
40
164
40


Packaging
Dimension, D X W X H mm
920X380 X1025
700X385 X1071
920X380 X1025
700X385 X1071
920X380 X1025
700X385 X1071
Packaging
Net weight (kg)
127
45
182
47
182
47
Environment
Operation temperature
0 ~ 40°C (the battery life will down when > 25°C)
Operation humidity
<95 % and non-condensing
Operation altitude**
<1000m
Acoustic noise level
Less than 60dB @ 1 meter
Less than 65dB @ 1 meter
Management
Smart RS-232 or USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser

HTT Series Specification
Model
HTT-30kVA
HTT-40kVA
HTT-50kVA
HTT-60kVA
HTT-80kVA
HTT-100kVA
HTT-120kVA
Capacity
30kVA/30kW
40kVA/36kW
50kVA/45kW
60kVA/60kW
80kVA/72kW
100kVA/90kW
120kVA/108kW
Mains input(AC)
Phase
3 phase +N+PE
Voltage range
291~492 V(line-line) full load; 200V~291V linearly decrease
Frequency range
35Hz~70Hz
THDi
<3% (full linear load)
Power factor
0.995
Bypass range
-10%~10% (can customized -10%~-30%, +10%~+20%)
Battery
Connection type
Positive series and negative series battery
Rated voltage
+180Vdc~ +300Vdc,-180Vdc~ -300Vdc
Battery number
30-50pcs/set (even number optional)
Charging current
can be set according to battery capacity
Output(inverter)
Output voltage
380VAC 3 phase+N+PE
Voltage regulation
<±1%
Phase lock range
50Hz/60Hz±5Hz(self frequency 50Hz/60Hz±0.01Hz)
Output frequency
50Hz/60Hz±0.01Hz(turn into mains frequency if phase locked)
Power factor
1
0.9
0.9
1
0.9
0.9
0.9
Crest factor
3:1
THDu
THD≤2.0% (linear load), THD≤3%(non-linear load)
Three phase voltage unbalance degree

Balance load: ≤0.5% 100% Unbalance load : ≤1%
Dynamic voltage transient range

≤5%
Transient recovery time

≤20ms
Three phase voltage deviation

Mains:0.4°; Battery :0.3°
Transfer time
Mains to battery: 0ms; Inverter to bypass: 0ms
Overload capacity
125% for 10min: 150% for 1min; >150% for 200ms (linear load)
System efficiency
>95%
Environment indicator
Noise
<65dB @100%load, cooling fan adopt intelligent speed control
Display
Touch screen LCD+LED
Interface
Standard: RS232, RS485, dry contacts;(SNMP card optional)
Operation temperature
Temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C,Altitude(m): <1000, 1000m-2000m above every 100m reduce 1%
IP class
IP30( Removable dust filter)
Physical specifications
Cabinet size (W*D*H)
420*750*880
600*800*1250
Cabinet weight KG
80
85
85
210
230
235
250
NOTES: Subject to change without further notice!
Model
HTT-150kVA
HTT-200kVA
HTT-300kVA
HTT-400kVA
HTT-500kVA
Capacity
150kVA/135kW
200kVA/180kW
300kVA/270kW
400kVA/360kW
500kVA/450kW
Mains input(AC)
Phase
3 phase +N+PE
Voltage range
291~492 V(line-line) full load; 200V~291V linearly decrease
Frequency range
35Hz~70Hz
THDi
<3% (full linear load)
Power factor
0.995
Bypass range
-10%~10% (can customized -10%~-30%, +10%~+20%)
Battery
Connection type
Positive series and negative series battery
Rated voltage
+180Vdc~ +300Vdc,-180Vdc~ -300Vdc
Battery number
30-50pcs/set (even number optional)
Charging current
can be set according to battery capacity
Output(inverter)
Output voltage
380VAC 3 phase+N+PE
Voltage regulation
<±1%
Phase lock range
50Hz/60Hz±5Hz(self frequency 50Hz/60Hz±0.01Hz)
Output frequency
50Hz/60Hz±0.01Hz(turn into mains frequency if phase locked)
Power factor
0.9
0.9
0.9
0.9
0.9
Crest factor
3:1
THDu
THD≤2.0% (linear load), THD≤3%(non-linear load)
Three phase voltage unbalance degree

Balance load: ≤0.5% 100% Unbalance load : ≤1%
Dynamic voltage transient range

≤5%
Transient recovery time

≤20ms
Three phase voltage deviation

Mains:0.4°; Battery :0.3°
Transfer time
Mains to battery: 0ms; Inverter to bypass: 0ms
Overload capacity
125% for 10min: 150% for 1min; >150% for 200ms (linear load)
System efficiency
>95%
Environment indicator
Noise
<65dB @100%load, cooling fan adopt intelligent speed control
Display
Touch screen LCD+LED
Interface
Standard: RS232, RS485, dry contacts;(SNMP card optional)
Operation temperature
Temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C,Altitude(m): <1000, 1000m-2000m above every 100m reduce 1%
IP class
IP30( Removable dust filter)
Physical specifications
Cabinet size (W*D*H)mm
600*1100*2000
600*1100*2000
1200*1100*2000
Cabinet weight (KG)
415
460
520
620
920