Tehnical Data of G10/ FR4 Epoxy Fiberglass Sheet
|
|
|
|
|
||||
PROPERTIES
|
UNIT
|
METHODE
|
STANDARD VALUE
|
TESTING RESULT
|
||||
Flexural strength perpendicular to laminations – under normal room temperature
|
MPa
|
ISO 178
|
≥ 350
|
360
|
||||
Notch Impact strength parallel to lamination (Notched charpy)
|
kJ/m2
|
ISO 179
|
≥ 37
|
45
|
||||
Dielectric strength perpendicular to laminations (in oil 90±2℃), 1.0mm in thickness
|
kV/mm
|
IEC 60243
|
≥ 14.2
|
20.5
|
||||
Breakdown voltage parallel to laminations (in oil 90±2℃)
|
kV
|
IEC 60243
|
≥ 3.5
|
40
|
||||
1MHz dielectric coefficient1MHz
|
-
|
IEC 60250
|
≤ 5.5
|
4.9
|
||||
1MHz loss factor1MHz
|
-
|
IEC 60250
|
≤ 0.04
|
0.013
|
||||
Water absorption rate, 1.6mm in thickness
|
%
|
ISO 62
|
≤ 0.25
|
0.02
|
||||
Insulation resistance Impregnated in water(22℃, 50%RH)
|
Ω
|
IEC 60093
|
≥5.0×1010
|
5.6×1010
|
||||
Flammability
|
class
|
IEC 60093
|
FV0
|
FV0
|
||||
Density
|
g/cm3
|
-
|
1.9-2.2
|
2.1
|