Computerized Non contact tonometer TOPCON CT-80
Feature
It’s Topcon’s solution for the further pursuit of
operational use and speedy measurement, relieving
patient’s discomfort to its minimum.
Specification
30% Faster interval time
The CT-80A/CT-80 provide easier and faster operation with
the aid of a new alignment bar and an improved air cylinder.
The interval between measurements has been reduced by
over 30%, so patients may be
examined more comfortably
in a shorter period of time.
Once the alignment has been
completed, the resulting data
are automatically measured
and displayed.
The 3D Auto alignment (CT-80A only) frequent blinking.
The 3D Auto Alingment System offers an easy operation and speedy measurement even for patients with difficult fixation.
Flex control function (CT-80A only)
With Auto-alignment on, you can pick the perfect timing for the measurement, minimizing patient’s discomfort. This is very suit able for difficult patients with moving eye and frequent blinking.
Built-in self check function
The CT-80A/CT80 lets the operator know in advance when maintenance is needed. it displays a warning message on the monitor when a lens is dirty, and also which lens it is (the measurement glass or the chamber glass).
Triple safety function
The CT-80A/CT80 features an innovative triple safety function.First the operator may set an adjustable safety stopper.
Second, a “too close” display on the monitor guides theuser in alignment. Third, an audible warning buzzer informs the operator if the cornea and the instrument are too close.
Speedy built-in printer
At a touch of a button, the CT-80A/CT80 provides highspeed printout of measured data in about a couple of
seconds! up to three individual measurements plus an averaged value will be printed out.
Optional manual control
The CT-80A/CT80 can be operated in a fully manual mode by overriding the automatic measurement setting.
Internal fixation target
Infrared lighting provides the main illumination for the CT-80A/CT-80: eliminating the need for harsh, bright
alignment lighting and increasing patient comfort.
Dual sensor system
The Topcon CT-80A/CT80
incorporates an original
measurement method
using two sensors; one
for light and one for
pressure. When the air
puff applanates the cornea, a light sensor detects the
applanation moment, while at the same time another sensor
monitors the internal chamber to obtain the intraocular
pressure. This new calculating system allows the operator to
obtain highly precise and accurate measurement data
without influence of atmospheric pressure, altitude or any
possible mechanical degradation.