Name |
Reagent Test Kit |
Spec |
10/20/25 Test/Box |
Principle |
Competition principle, based on proximity hybridization-regulated CRET |
Intended Use |
Used as an aid in the assessment of vitamin D sufficiency |
Storage and Exp. Date |
Stable for 18 months when stored at 2-8℃ away from light |
Applicable Instruments |
Chemiluminescence immunoassay analyzer (HSCL-5000) produced by Nanjing Poclight Biotechnology Co. Ltd. |
Test Method |
The test method is homogeneous chemiluminescence immuoassay |
The test method is homogeneous chemiluminescence immuoassay
1. Preparation before testing:
1.1 Please read this manual and the instrument manual carefully before use.
1.2 Check whether the instrument can work normally, whether the reaction cup or sample tube, substrate solution and buffer are prepared adequately, and prepare other related consumables.
2. Test procedure
2.1 Turn on the chemiluminescence immunoassay analyzer.
2.2 Check whether the calibration card is consistent with the lot number of the kit and scan the calibration card.
2.3 Absorb 100µL of the sample to be tested and 200µL of the dissociation solution into the reaction cup and mix well; put into the instrument; start incubation, measurement, processing data; and derive the test results.
2.4 Total assay time is 10 minutes.
3. Result analysis.
The measured chemiluminescence intensity is converted from the standard curve to obtain the concentration of 25 (OH) VD in the unknown sample, which can be read at the ng/mL level.
4. Calibration
Each kit batch contains its specific calibration information, which is stored on a calibration card.
CAUTION
1. This product is a single use in vitro diagnostic reagent, please do not reuse it, and do not use the expired product.
2. The reagent can only be used on the supporting instrument analysis system.
3. The test procedure must be followed as indicated, improper operation will lead to wrong results.
4. Components of kits with different lot numbers cannot be mixed.
5. The calibration card used for calibration should not be exchanged with kits of different lot numbers.
6. Do not swallow the reagents or contact with skin, eyes or mucous membranes as the reagents contain preservatives; once contacted, rinse the contaminated area with water.
7. When using the instrument for testing, each sample and the corresponding reagents should be replaced with a new disposable tip to avoid cross-contamination, which may affect the accurate determination of 25 (OH) VD concentration in the sample, and all samples should be aspirated directly to the bottom of the sample tube.
8. The use of fresh samples is recommended. All samples from patients should be treated as potential sources of infection and all waste generated during the test must be disposed of in accordance with local regulations.
9. If the reagent has exceeded its expiration date, it should not be used again.
10. This kit contains animal-derived components that are potentially infectious
.
We have CE, SGS, ISO certification, and more than ten technical patents.
Our products are sold all over the world and we have established a good cooperative relationship with many customers.
We support all kinds of express delivery and remittance.
FAQ
Q: What is the method u use to do the test?
A: Homogeneous chemiluminescence immuoassay.
Q: How can I get the suitable product and price ?
A: You can advice your exactly specs details to us.
Q: D o you accept small order?
A: No matter how many products you order, we welcome them and look forward to long-term cooperation.
Q: What is the MOQ?
A: No MOQ request, but our reagent and our equipment need to be used together. Of course, the more the quantity, the cheaper the price.
Q: Do you offer OEM service?
A: No doubt. We supply OEM service for many years.
Q: Why Choose you?
A: We are the leading medical devices factory in China.
We are Alibaba gold supplier, obtained ISO13485 certification, CE certification, SGS and so on.
Best service and quality with competitive price.
Contact information