Biochemical orbital shaker incubator with digital temperature controller
Open type incubated shaker /orbital shaker incubator
Features of orbital shaker incubator:
1. Well constructed for long term operation.
2. Advance technology ensuring mechanical stability and reliability of operation.
3. Shaking mechanism is constructed with chromium alloy material and high quality cast iron.
4. Circuit breaker protect against excess current, power-off memory to return to original setting, soft start prevents splashing, auto cut-off if motor overheat.
5. Precision microprocessor control system, accuracy of speed ± 1rpm.
6. Brushless high torque motor, maintenance free.
Parameters of orbital shaker incubator:
Model |
HNY-810 |
HNY-820 |
HNY-850 |
HNY-880 |
Control mode |
P.I.D microcomputer processing chip |
|||
Oscillation mode |
convolution |
Reciprocate |
convolution |
Reciprocate |
Display |
LED digital display |
|||
Cyclotron frequency range |
30-300rpm/min |
|||
Cyclotron accuracy |
±1 |
|||
Shake plate shimmy range(mm) |
Ø26
|
|||
Max configuration |
100ml*22/250ml*12/500ml*8 |
250ml*92/500ml*66/1000ml*36(double)
|
||
Standard configuration |
250ml*12 |
250ml*46(double) |
||
Plate size(mm) |
430*325 |
800*600 |
||
Plate number |
1 |
2(double) |
||
Size(mm) |
456*380*195 |
900*640*780(double) |
||
Power(w) |
80 |
200 |
||
Voltage |
AC220±10% 50-60HZ |
Table-top type shaking incubator /orbital shaker incubator:
Control Feature:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted.
Structure Feature:
Sort: Microcomputer LCD type
Performance Feature:
1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations
3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
4.Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs.
5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples.
7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.
Orbital shaker incubator Parameters:
Model |
HNY-209 |
HNY-100B |
HNY-100D |
HNY-200B |
HNY-200D |
Control mode |
P.I.D microcomputer processing chip |
||||
Convection mode |
Forced convection |
||||
Oscillation mode |
convolution |
||||
Display |
LED digital display |
LCD display |
|||
USB data download system |
No |
Yes |
|||
Cyclotron frequency range |
40-500rpm/min |
30-600rpm/min |
|||
Cyclotron frequency accuracy |
±1rpm |
||||
Shake plate shimmy range(mm) |
Ø26
|
Ø26
|
Ø0-50
|
Ø26
|
Ø0-50
|
Max configuration |
50ml*16/100ml*10/ 250ml*8 |
100ml*23/250ml*12/500ml*9/1000ml*5 |
|||
Standard configuration |
50ml*4/100ml*3/ 250ml*3 |
500ml*3 250ml*3 100ml*4 50ml*4 |
500ml*3 250ml*4 100ml*5 50ml*5 |
||
Pallet size(mm) |
220*280 |
450*410 |
410*360 |
450*410 |
410*360 |
Timing(h) |
0-166 |
0-999 |
|||
Temp.range(°C) |
10-60 |
Ambient temp.+5-60 |
4-60 |
||
Temp. accuracy(°C) |
±0.1 |
||||
Temp. uniformity(°C) |
≤0.5(37°C) |
||||
Temp. fluctuation(°C) |
≤0.2(37°C) |
||||
Pallet number |
1 |
||||
Size(mm) |
550*510*440 |
740*710*510 |
|||
Volume(L) |
26 |
70 |
|||
Power(w) |
300 |
550 |
650 |
650 |
650 |
Voltage |
AC220±10% 50-60HZ |
||||
Ambient temp. |
5-25 |
Vertical type rocking incubator/orbital shaker incubator:
Summary:
This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency
Control feature:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted
Structure feature:
Sort: Microcomputer LCD type
Performance feature of orbital shaker incubator:
1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations
3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
4.Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs.
5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples.
7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.
Parameters of orbital shaker incubator:
Model |
HNY-1102C |
HNY-2102C |
HNY-1102 |
HNY-2102 |
HNY-1112B |
HNY-2112B |
HNY-1112F |
HNY-2112F |
||
Control mode |
P.I.D microcomputer processing chip |
|||||||||
Convection mode |
Forced convection |
|||||||||
Oscillation mode |
convolution |
Reciprocate |
||||||||
Display |
LCD display |
|||||||||
USB data download system |
Yes |
|||||||||
Kudan control system |
Yes |
|||||||||
Cyclotron frequency range |
30-300rpm/min |
30-280rpm/min |
||||||||
Cyclotron frequency accuracy |
±1 |
|||||||||
Shake plate shimmy range(mm) |
Ø26 |
Ø26(Ø35) |
0-50 |
|||||||
Max configuration |
100ml*48/250ml*24/ 500ml*24 |
100ml*90/250ml*56/500ml*48 |
250ml*90/500ml*74/1000ml*36 |
|||||||
Standard configuration |
250ml*24 |
250ml*28 500ml*22 |
250ml*45 500ml*36 |
|||||||
Pallet size(mm) |
500*350 |
745*450 |
970*560 |
|||||||
Timing(h) |
0-999 |
|||||||||
Temp. range(℃) |
Ambient temp.+5-60 |
4-60 |
Ambient temp.+5-60 |
4-60 |
Ambient temp.+5-60 |
4-60 |
Ambient temp.+5-60 |
4-60 |
||
Temp.accuracy |
±0.1℃ |
|||||||||
Temp. uniformity(℃) |
≤0.5(37℃) |
|||||||||
Temp. fluctuation(℃) |
≤0.2(37℃) |
|||||||||
Plate number |
2 |
|||||||||
Size(mm) |
700*560*1260 |
950*700*1260 |
1200*820*1560 |
|||||||
Volume(L) |
175 |
335 |
580 |
|||||||
Power(w) |
600 |
850 |
900 |
1150 |
1100 |
1400 |
1100 |
1400 |
||
Voltage |
AC220±10% 50-60HZ |
|||||||||
Ambient temp.(℃) |
5-25 |
Horizontal type incubator shaker series:
Summary of orbital shaker incubator:
This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency.
Control feature of orbital shaker incubator:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system
Structure Feature:Sort: Microcomputer LCD type
Performance feature of orbital shaker incubator:
1 P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2 The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
3 Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs. Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
4 Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples. The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window. Use of microcomputer intelligent control system, powerful, strong anti-interference ability.
5 Can achieve the 1-24 time period of the day and night free combination of temperature and illumination parameters of ten sections of programming. Whole quiet design, electrostatic spray cabinet with tempered glass observation window, always observe the inside temperature and light conditions.
6 The top of the built-in light, special biological light source spectral characteristics, high strength, fever, particularly suitable for the experimental requirements
Parameters of orbital shaker incubator:
Model |
HNY-111A |
HNY-211A |
HNY-111B |
HNY-211B |
HNY-111C |
HNY-211C |
HNY-111F |
HNY-211F |
|||
Control mode |
P.I.D microcomputer processing chip |
||||||||||
Convection mode |
Forced convection |
||||||||||
Oscillation mode |
convolution |
Reciprocate |
|||||||||
Display |
LCD display |
||||||||||
USB data download system |
Yes |
||||||||||
Kudan control system |
Yes |
||||||||||
Lllumination |
4 12000LX(max) |
No |
|||||||||
Cyclotron frequency range |
30-300rpm/min |
||||||||||
Cyclotron frequency accuracy |
±1 |
||||||||||
Shake plate shimmy range(mm) |
Ø26 |
0-50 |
|||||||||
Max configuration |
100ml*66/250ml*45/ 500ml*28 100ml*18/2000ml*11 |
250ml*45/500ml*28/1000ml*18/2000ml*11/5000ml*6 |
250ml*46/500ml*33/1000ml*18 |
||||||||
Standard configuration |
500ml*28 |
2000ml*8 |
500ml*33 |
||||||||
Pallet size(mm) |
920*510 |
800*520 |
|||||||||
Timing(h) |
0-999 |
||||||||||
Temp. range(℃) |
Ambient temp.+5-60 |
4-60 |
Ambient temp.+5-60 |
4-60 |
Ambient temp.+5-60 |
4-60 |
Ambient temp.+5-60 |
4-60 |
|||
Temp.accuracy |
±0.1℃ |
||||||||||
Temp. uniformity(℃) |
≤0.5(37℃) |
||||||||||
Temp. fluctuation(℃) |
≤0.2(37℃) |
||||||||||
Plate number |
1 |
||||||||||
Size(mm) |
1200*740*800 |
1200*740*1000 |
1200*740*800 |
||||||||
Volume(L) |
188 |
260 |
188 |
||||||||
Power(w) |
1100 |
1300 |
650 |
900 |
650 |
950 |
650 |
900 |
|||
Voltage |
AC220±10% 50-60HZ |
||||||||||
Ambient temp.(℃) |
5-25 |
Terms of payment: 100% T/T in advance and Western Union.
Package: Wooden case.
Delivery time: within 10 days after received your payment.
Warranty: one year.
Pre-sale service
Contract execution
After-sale service
1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except wear parts. You can also buy parts from us after 12months.
1.Company Show