12V 24V 48V 40A auto MPPT solar controller MPPT solar charge controller MPPT solar regulator
1.MPPT charging mode, conversion efficiency as high as 99%, comparable to use traditional controller to save 30%~60% solar panels.
2.High efficiency MPPT operation scheme, and use the TI28035 chip, make solar panels utilization rate for 99%.
3.Intelligent design, online upgrade, customer can enjoy lifelong upgrade services.
4.Products comply with 2001/95/EC environmental protections requirements, no cadmium hydride and fluoride etc.
5.The components are brand, high temperature resistant not less than 105°C,the theoretical design life for ten years.
6.Charging ways: three order imitation(constant current, constant voltage, floating).
7.12V/24V/48V automatic identification system, convenient to use.
8.Wide input voltage from solar panels, maximum DC 150V.
9.Advanced LCD and LED display various parameters.
10.RS232 communication, can provide communication protocol, convenient to manage unified.
11.Provide professional 11 languages on computer software, display the working condition and working parameters of system.
12.CE, FCC, ROSH, PSE certification.
13.2 years warranty , and can provide 3 ~ 10 years extended warranty service .
Parameters:
Model:XD-T-MPPTDC12V/24V/48V-series | 40A | 50A | 60A | |
Charge Mode | Maximum Power Point Tracking | |||
Method | 3 stages: fast charge(MPPT),constant voltage,floating charge | |||
System Type | DC12V/24V/48V | Automatic recognition | ||
System Voltage | 12V system | DC9V~DC15V | ||
24V system | DC18V~DC30V | |||
48Vsystem | DC36V~DC60V | |||
Soft Start Time | 12V/24V/48Vsystem | ≤10S | ||
Dynamic Response Recovery Time | 12V/24V/48Vsystem | 500us | ||
Conversion Efficiency | 12V/24V/48Vsystem | ≥96.5%,≤99% | ||
PV Modules Utilization Rate | 12V/24V/48Vsystem | ≥99% | ||
Input Characteristics | ||||
MPPT Working Voltage and Range | 12V system | DC18V~DC150V | ||
24V system | DC34~DC150V | |||
48V system | DC65~DC150V | |||
Low Voltage Input Protection Point | 12V system | DC16V | ||
24V system | DC30V | |||
48V system | DC60C | |||
Low Voltage Input Recovery Point | 12V system | DC22V | ||
24V system | DC34V | |||
48V system | DC65V | |||
Max DC Voltage | 12V/24V/48V system | DC160V | ||
Input Overvoltage Protection Point | 12V/24V/48V system | DC150V | ||
Input Overvoltage Recovery Point | 12V/24V/48V system | DC145V | ||
Max. PV Power | 12V system | 570W | 700W | 900W |
24V system | 1130W | 1400W | 1700W | |
48V system | 2270W | 2800W | 3400W | |
Output Characteristics | ||||
Selectable Battery Types (Default type is GEL battery) | 12V/24V/48V system |
Sealed lead acid, vented, Gel, NiCd battery
(Other types of the batteries also can be defined) |
||
Constant Voltage | 12V/24V/48V system | Please check the charge voltage according to the battery type form. | ||
Floating Charge Voltage | 12V/24V/48V system | |||
Over Charge Protection Voltage | 12V system | 14.6V | ||
24V system | 29.2V | |||
48V system | 58.4V | |||
Rated Output Current | 12V/24V/48V system | 40A | 50A | 60A |
Current-limiting Protection | 12V/24V/48V system | 44A | 55A | 66A |
Temperature Factor | 12V/24V/48V system | ±0.02%/°C | ||
Temperature Compensation | 12V/24V/48V system | 14.2V-(The highest temperature)*0.3 | ||
Output Ripples(peak | 12V/24V/48V system | 200mV | ||
Output Voltage Stability Precision | 12V/24V/48V system | ≤±1.5% | ||
Display | ||||
LCD display |
Input,output parameter and output power etc
(check the LCD display instruction) |
|||
LED display |
3 LEDs indicates:Fault indicate light,charge indicate light,
power source indicate light(check the LED instruction) |
|||
Software Control through PC(communication port) | RS232 (matching) or LAN(optional) | |||
Protection | ||||
Input Low Voltage Protection | Check the input characteristics | |||
Input Overvoltage Protection | Check the input characteristics | |||
Input Polarity Reversal Protection | yes | |||
Output Overvoltage Protection | Check the output characteristics | |||
Output Polarity Reversal Protection | yes | |||
Short-circuit Protection |
Recover after eliminating the Short-circuit fault,no problem for
long term Short-circuit |
|||
Temperature Protection | 95°C | |||
Temperature protection | Above 85°C ,decrease the output power,decrease per degree. | |||
Other Parameters | ||||
Noise | ≤40dB | |||
Thermal methods |
Forced air cooling,fan speed rate regulated by temperature,when inner temperature is too low,fan ran slowly or stop;
when controller stop working,fan also stop ran. |
|||
Components |
World brand raw materials. Compliance with EU standards.
All rated temperature of electrolytic capacitors not less than 105°C |
|||
Smell | No peculiar smell and and toxic substances. | |||
Environment Protection | Meet the 2002/95/EC,no cadmium hydride and fluoride | |||
Physical | ||||
Measurement DxWxH(mm) | 270*185*90 | |||
N.G(kg) | 3 | |||
G.N(kg) | 3.6 | |||
Colo | Blue/Green(optional) | |||
Safety | CE,RoHS, PSE,FCC | |||
EMC | EN61000 | |||
Type of Mechanical Protection | IP21 | |||
Environment | ||||
Humidity | Atmospheric Pressure | |||
Altitude | 0~3000m | |||
Operating Temperature | ()-20°C~+40°C | |||
Storage Temperature | ()-40°C~+75°C | |||
Atmospheric Pressure | 70~106kPa |