Model: CM-
|
|
30A
|
40A
|
50A
|
60A
|
80A
|
||||||
Charging Mode
|
MPPT Automatic Maximum Power Point Tracking
|
|
|
|
|
|
||||||
Charging Method
|
Three stages: Constant Current (MPPT), Balanced Charging, Floating Charge
|
|
|
|
|
|
||||||
System Type
|
12V/24V/48V
|
Automatic Identification/Manual Setting
|
|
|
|
|
||||||
System Identification Voltage Range
|
12V System
|
DC 9V - DC 15V
|
|
|
|
|
||||||
|
24V System
|
DC 18V - DC 30V
|
|
|
|
|
||||||
|
48V System
|
DC 36V - DC 60V
|
|
|
|
|
||||||
Soft Start Time
|
12V/24V/48V
|
≤ 10ms
|
|
|
|
|
||||||
Dynamic Response Recovery Time
|
12V/24V/48V
|
≤ 500us
|
|
|
|
|
||||||
Static Power
|
12V/24V/48V
|
≤ 2W
|
|
|
|
|
||||||
Machine Efficiency
|
12V/24V/48V
|
≥ 96.5%/99%
|
|
|
|
|
||||||
PV Module Utilization
|
12V/24V/48V
|
≤ 99%
|
|
|
|
|
||||||
Input Characteristics
|
|
|
|
|
|
|
||||||
MPPT Operating Voltage Range
|
12V System
|
DC 18V - DC 150V
|
|
|
|
|
||||||
|
24V System
|
DC 34V - DC 150V
|
|
|
|
|
||||||
|
48V System
|
DC 65V - DC150V
|
|
|
|
|
||||||
Maximum Solar Panel Input Power
|
12V System
|
420W
|
570W
|
700W
|
900W
|
1100W
|
||||||
|
24V System
|
840W
|
1130W
|
1400W
|
1700W
|
2200W
|
||||||
|
48V System
|
1650W
|
2270W
|
2800W
|
3400W
|
4400W
|
||||||
Output Characteristics
|
|
|
|
|
|
|
||||||
Optional Battery Type (Default Is Lead-acid Maintenance- free Battery)
|
12V/24V/48V
|
Lead-acid Maintenance-free Battery, Gel Battery, Liquid Battery, Lithium Battery (Can Also Be Customized For Other Types Of Battery)
|
|
|
|
|
||||||
Current Limiting Protection
|
12V/24V/48V
|
32A
|
42A
|
52A
|
62A
|
82A
|
||||||
Temperature Coefficient
|
12V/24V/48V
|
± 0.02%/℃
|
|
|
|
|
||||||
Temperature Compensation
|
12V/24V/48V
|
14.2V-(Maximum Temperature -25℃)*0.3
|
|
|
|
|
||||||
Output Regulation Accuracy
|
12V/24V/48V
|
≤ ±1.5%
|
|
|
|
|
||||||
Protection
|
|
|
|
|
|
|
||||||
Input Low Voltage Protection
|
|
Reference Input Characteristics
|
|
|
|
|
||||||
Input High Voltage Protection
|
|
Reference Input Characteristics
|
|
|
|
|
||||||
Short Circuit Protection
|
|
After 5 Trial Starts Will Enter The Protection State, Restart Recovery
|
|
|
|
|
||||||
Temperature Protection
|
|
90℃
|
|
|
|
|
||||||
Temperature Rise Protection
|
|
Reduce Power Output When Exceed 85℃
|
|
|
|
|
||||||
Other Parameters
|
|
|
|
|
|
|
||||||
Noise
|
|
≤ 50dB
|
|
|
|
|
||||||
Heat Dissipation Method
|
|
Forced Air Cooling, Fan Speed Is Adjusted By Temperature
|
|
|
|
|
||||||
Mechanical Protection Type
|
|
IP21
|
|
|
|
|
||||||
Humidity
|
|
0 - 90%RH (No Condensation)
|
|
|
|
|
||||||
PV Module Configutation
|
|
|
|
|
|
|
||||||
System Battery Voltage
|
|
PV Module Load Voltage (Recommended Value)
|
|
|
|
|
||||||
12V System
|
|
18V-60V (30V Module*1 String, 36V Module*1 String)
|
|
|
|
|
||||||
24V System
|
|
36V-72V (30V Module*2 String, 36V Module*2 String)
|
|
|
|
|
||||||
48V System
|
|
72V-144V (30V Module*3 String, 36V Module*3 String)
|
|
|
|
|