Phenomenon
|
Solution
|
OPL1220
|
|
OPL1230
|
OPL4820
|
OPL4830
|
OPL4830
|
||||||
Under the sunshine, the indicator light (NO.1) of solar panel is off
|
Please check the line to photocell and make sure the proper connection
|
|
|
|
48V
|
|
|
||||||
As the cell panel is charged, the indicator light (NO.1) flashes quickly
|
The system is over-voltage. Please check whether the storage battery is well connected, or its voltage is too high
|
20A
|
|
30A
|
20A
|
30A
|
30A
|
||||||
The indicator light (NO.2) of storage battery is off
|
Please check whether the storage battery is well connected
|
20A
|
|
30A
|
20A
|
30A
|
30A
|
||||||
The indicator light (NO.2) of storage battery is red without output
|
The storage battery is over-discharged
|
|
|
|
<80V
|
|
|
||||||
The indicator light (NO.3) of load flashes slowly without output
|
The load power is higher than the rated power, please stop the operation of some equipment which consumes power, and then press
the key for a long time |
|
B02 Gel
|
|
B03 flood
|
|
|
||||||
The indicator light (NO.3) of load flashes quickly without output
|
The load is short circuit and need to be adjusted. Then press the key for a longer time or wait till the next day, it will restart
to work |
|
14.2V
|
|
14.6V
|
|
|
||||||
The indicator light (NO.3) is on continually without output
|
Please check whether the equipment which consumes power is well connected
|
|
|
|
|
|
|
||||||
Others
|
Please check the connection, 12/24V Auto identified
|
|
|
|
|
|
|
||||||
Discharge reconnect
|
12.6V(defaul,adjustable)
|
|
|
|
|
|
|
||||||
USB output
|
5V/3A
|
|
|
|
|
|
|
||||||
Self-consume
|
<10mA
|
|
|
|
|
|
|
||||||
Operating temperature
|
-35~+60 ℃
|
|
|
|
|
|
|
||||||
Size/Weight
|
150*78*35mm /150g
|
|
|
|
|
|
|
||||||
*Product specifications are subject to change without prior notice.
|
|
|
|
|
|
|
|
||||||
The Equalization/float charge/dicharge stop/discharge reconnect rate x2 when 24vdc input,x4 when