Model
|
|
BU60-1204C
|
BU120-1208C
|
BU240-1216C
|
|||
Input
|
Voltage Range
|
220V(±10)
|
|
|
|||
|
Frequency Range
|
50/60Hz
|
|
|
|||
|
Efficiency
|
≥83%
|
≥90%
|
≥90%
|
|||
|
Alternating Current
|
1.6A Max
|
2.0A Max
|
3.2A Max
|
|||
|
Inrush Current
|
≤60A(230V~full load)
|
|
|
|||
|
Leakage Current
|
<10mA/3000V~
|
<10mA/3000V~
|
<10mA/3000V~
|
|||
|
Applicable Battery
|
12V/7Ah Built-in
|
|
|
|||
Ouput
|
DC Voltage
|
12V
|
12V
|
12V
|
|||
|
Rated Current
|
5A
|
10A
|
20A
|
|||
|
Rated Power
|
60W
|
120W
|
240W
|
|||
|
Output Channel
|
4CH
|
9CH
|
18CH
|
|||
|
Protection Current
|
1.35A Max
|
1.1A Max
|
1.1A Max
|
|||
|
Ripple and Noise
|
≤150mV
|
|
|
|||
|
Linear Adjustment
|
±3%
|
±3%
|
±3%
|
|||
|
Load Adjustment
|
±5%
|
±5%
|
±5%
|
|||
|
Load Loss
|
≤1.5W
|
≤2W
|
≤3W
|
|||
|
Start / Rise Time
|
≤3s,≤30ms(230V~full load)
|
|
|
|||
|
Hold Time
|
≥5ms
|
|
|
|||
Protection
|
Overcurrent
|
6~8A
|
16~18A
|
24~28A
|
|||
|
|
Protection Mechanism : Hiccup Mode
|
|
|
|||
|
Overvoltage
|
18V Max
|
|
|
|||
|
|
Protection mechanism: output lock is closed, the fault is removed and the power is restored after restarting
|
|
|
|||
|
Short Circuit
|
Protection mechanism: output lock is closed, automatic recovery after removing the fault
|
|
|
|||
Environment
|
Operating Temperature
|
-20℃—+45℃
|
|
|
|||
|
Working Humidity
|
20%—90% RH,No condensation
|
|
|
|||
|
Storage temperature and humidity
|
-25℃—+65℃,10%—95% RH
|
|
|
|||
|
Temperature Coefficient
|
±0.03%/℃(0—50℃)
|
|
|
|||
|
Anti-vibration Performance
|
5—44Hz,10 minutes/cycle, duration 60 minutes
|
|
|
|||
Remarks
|
*Unless otherwise specified, all specifications are measured at an input of 230V~, rated load, and 25°C ambient temperature
*Ripple and noise measurement method: use a 12″ twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal,and measure under 20MHz bandwidth *Error: Including setting error, linear adjustment rate and load adjustment rate *For output under low voltage input, please refer to the static characteristic curve *For all EMC tests, the test sample is installed on an iron plate with a thickness of 1mm, a length of 720mm, and a width of 360mm. * When the altitude exceeds 2000 meters, the ambient temperature drops by 3.5℃/1000 meters |
|
|
|
Container
|
Door Openings
|
|
Internal Dimensions
|
|
|
Weight/kg
|
|
|
CBM
|
|||||
|
Width
|
Height
|
Length
|
Width
|
Height
|
Max G.W
|
Tare
|
Max Payload
|
|
|||||
20GP
|
2438 mm
|
2591 mm
|
5898 mm
|
2352mm
|
2393
mm
|
30480
KGS
|
2185
KGS
|
28295
KGS
|
28m³
|
|||||
40GP
|
2438mm
|
2591 mm
|
12032mm
|
2352mm
|
2393
mm
|
32500
KGS
|
3740
KGS
|
28760
KGS
|
54m³
|
|||||
40HQ
|
2438mm
|
2896 mm
|
12032mm
|
2352mm
|
2698
mm
|
32500
KGS
|
3840
KGS
|
28660
KGS
|
68m³
|