Technical parameters of water flow meter:
Main power |
AC220V 50HZ / DC24V |
|
Power consumption |
<15W (And set with sensor supporting power consumption ) |
|
Display and push buttons |
The big screen LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as alarm display ,four thin-film touch nubs ,which is used to data set . |
|
Accumulator |
Forward total quantity ,reverse total quantity |
|
Output signal |
Analog output |
Bi-direction with two ways ,Isolation 0-10mA/4-20mA |
Load resistor:0-10Ma;0-1.5KΩ;4-20Ma;0-750Ω |
||
Frequency output |
Forward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50Ma when the transistor is turned on |
|
Alarm output |
Two outputs from the collectors of photoelectric isolate transistors are for alarm signals .The external voltage must be lower than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty ,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits. |
|
Pulse output |
For pulse output in forward and reverse flow measurement ,upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P .The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on . |
|
Accuracy |
±1.5% of the value displayed ,±1.0% are selectable. |
|
Damping time constant |
Continuous variable from 0-100 s (90%)can be selected by group |
|
Communication |
RS232 ,RS485 or HART Communication are selectable ,with lighting resistance |
|
Power failure |
An anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years) |
|
Protection class |
IP65 |
|
Ex-proof Mark |
Exd IIBT4 |
Main performances of the liner materials:
Liner material |
Liner material |
Applications |
PTFE |
1.The most steadiest material in plastics which is resistance to boiling hydrochloric acid ,vitriol and aqua regia as well as strong and organic impregnates.
|
Strong corrosive mediums such as strong acid and alkali |
ABS |
1.Be good of abration resistibility
3.Can be used for water;sewage water,acidic medium and so on. |
Applicable to water, sewage, acid, alkali and other liquid |
Our company has strict quality control from product design, raw material procurement and processing, manufacturing and assembly, inspection and verification to every stage of product release, scientific management, strict process, advanced equipment and Professional team as a guarantee of quality products.