Quick Details

Chargeable:
Yes
Battery Type:
Deep Cycle: Sealed Gel
Cycle Life:
3000
Storage Type:
Room temperature storage
Product Details
Product Description
Vrla Solar Energy Storage Lead Acid Batteries 12V 100Ah 150Ah 200Ah 250Ah Bateria De Deep Cycle Tubular Battery
Vrla Solar Energy Storage Lead Acid Batteries 12V 100Ah 150Ah 200Ah 250Ah Bateria De Deep Cycle Tubular Battery
Battery Configuration
Vrla Solar Energy Storage Lead Acid Batteries 12V 100Ah 150Ah 200Ah 250Ah Bateria De Deep Cycle Tubular Battery
Battery Terminal Options
Vrla Solar Energy Storage Lead Acid Batteries 12V 100Ah 150Ah 200Ah 250Ah Bateria De Deep Cycle Tubular Battery
T1 Terminal
FASTON TYPE (Copper) quick disconnect tabs; silver coating for better conductivity
T2 Terminal
FASTON TYPE (Copper) quick disconnect tabs; silver coating for better conductivity
T3 Terminal
Brass Coated With Tin
Torque: 3.9 ~ 5.4 N* m(34.39 ~ 47.75 in*lbs)
T4 Terminal
Brass Coated With Tin
T5 Terminal
Lead Torque: 3.9 ~ 5.4 N*m(34.39 ~ 47.75 in*lbs)
T6 Terminal
Brass Coated With Tin; Threaded Insert 6mm STUD Torque: 3.9 ~ 5.4 N*m(34.39 ~ 47.75 in*lbs)
T7 Terminal
Brass Coated With Tin; Threaded Insert 6mm STUD Torque: 3.9 ~ 5.4 N*m(34.39 ~ 47.75 in*lbs)
T9 Terminal
Lead Torque: 11 ~ 14.7 N*m(97.28 ~ 130.0 in*lbs)
Specification
Model
6-GFM(G)-100Ah
6-GFM(G)-150Ah
6-GFM(G)-200Ah
6-GFM(G)-250Ah
Cells Per Unit
6



Voltage Per Unit
12V



Capacity
100Ah@10hr-rate to 1.80V per cell @25°C
150Ah@10hr-rate to 1.80V per cell @25°C
200Ah@10hr-rate to 1.80V per cell @25°C
250Ah@10hr-rate to 1.80V per cell @25°C
Weight
29kg
42kg
58.5kg
67kg
Internal Resistance
Approx. 6mΩ
Approx. 4mΩ
Approx. 3.5mΩ
Approx. 2.5mΩ
Terminal
F1/F2

F1 / F2

Max. Discharge Current
1500A(5s)
2250A(5s)
3000A(5s)
3750A(5s)
Design Life
10~15 years
10~15 years


Maximum Charging Current
25A
37.5A
50A
62.5A
Float Charging Voltage
13.6 V~13.8 V @ 25°C
Temperature Compensation: -20mV/°C/Cell



Cycle Use Voltage
14.4 V~14.9 V @ 25°C
Cycle Use Voltage
Temperature Compensation: -30mV/°C/Cell



Operating Temperature Range
Discharge: -20°C~60°C
Charge: 0°C~50°C
Storage: -20°C~60°C



Advantages:
1. High purity lead-tin alloy, reduce battery self discharge rate and increase battery service life.
2. ABS battery case made by LG raw material to increase battery service life.
3. Heat sealing technique instead of glue sealing to increase the tightness and stability of battery.
4. TTP technique not only reduce internal resistance and material cost but also increase battery life.
5. Conduct four large current discharge texting before package to insure battery quality.
6. Full charge before delivery. Buy and use it directly.
Characteristics Data
Product Cetificate
Product Images
Factory Overview
Loading Pictures
Contact Us
FAQ
1.How long can a battery last?
The service design life of a battery varies considerably with how it is used, how it is maintained and charged, temperature, among other factors.

2. Do I need to add water to my battery?
No. Sealed lead acid batteries do not require the use of water.

3. What determines the life of a VRLA battery?
Sealed lead acid battery life is determined by many factors. These include temperature, depth and rate of discharge, and the number of charges and discharges (called cycles).

4. What is the difference between float and cycle applications?
A float application requires the battery to be on constant charge with an occasional discharge. Cycle applications charge and discharge the battery on a regular basis.

5. What is the definition of "cycle use" and "standby use"?
“Cycle Use” – direct power source: Cycle Use – IT can provide the power supply to power tools, and portable electronic products.It can also be used for cycling charging and discharging usage such as electronics motorbike or vacuum cleaner.
“Standby Use” – back up power: Standby Use is mainly used for emergency power to avoid future damage that may be caused by a sudden power outage.

6. When should a deep-cycle battery be used?
Deep-cycle batteries are used when 50% or more of the capacity is used per cycle. The most common use of deep-cycle batteries is in applications that require deep, repetitive drain, like powerful car audio systems, trolling motors, golf carts, electric wheelchairs, or RV house power sources. Public safety and high performance vehicles are other applications that call for the special characteristics of deep-cycle batteries.

7. How are batteries rated?
Lead acid batteries are rated based on a capacity given in a defined time. There is not a set industry standard for how to rate a battery.

If you want to know more information, you can send inquiry to our team, we will cover more details.