Model/PN
|
IOC060JY2
|
IOC120JY2
|
IOC150JY2
|
IOC180JY2
|
|||
Input Rating
|
400V±15% AC
|
|
|
|
|||
Power Factor
|
≥0.99
|
|
|
|
|||
Efficiency
|
≥94%
|
|
|
|
|||
Power Output
|
60kW
|
120kW
|
150kW
|
180kW
|
|||
Output Voltage
|
150-1000V DC
|
|
|
|
|||
Output Current (Per Connector)
|
100A MAX
|
200A MAX
|
250A MAX
|
250A MAX
|
|||
Electrical Protection
|
Over current, Short circuit, Over voltage, Under voltage, Ground fault, Lightning Surge, Over temperature
|
|
|
|
|||
Display
|
8" TFT LCD touch screen
|
|
|
|
|||
Supporting Language
|
English, Spannish, or other required local language
|
|
|
|
|||
User Authentication
|
RFID card reader, user name & password, mobile No. & pin code
|
|
|
|
|||
Payment Terminal
|
Payter, Nayax (Optional)
|
|
|
|
|||
Push Buttons
|
3 Physical buttons for Multi-functional purpose, Emergency stop
|
|
|
|
|||
Charge Options
|
Charge by duration, by energy, by amount
|
|
|
|
|||
Operating Temperature
|
(-30℃ to +55℃) in operation, (-40℃ to +75℃) in storage
|
|
|
|
|||
Working Humidity
|
95% relative humidity, non-condensing
|
|
|
|
|||
Altitude
|
Up to 6000 feet (2000 m)
|
|
|
|
|||
IP Performance
|
IP55
|
|
|
|
|||
Cooling
|
Forced air
|
|
|
|
|||
Charging Cable Length
|
16.4 ft (5 m), straight cable
|
|
|
|
|||
Dimension (H x W x D, mm)
|
2098x1122x912
|
|
|
2140x1150x1070
|
|||
Net Weight
|
330Kg
|
390Kg
|
420Kg
|
460Kg
|
|||
Network Interface
|
Ethernet,4G
|
|
|
|
|||
OCPP
|
OCPP1.6J, OCPP2.0.1
|
|
|
|
|||
Web Portal & Mobile App
|
Yes, ios/Android
|
|
|
|
|||
Certification
|
CE, IEC/EN 61851-1, IEC/EN 61851-23, IEC/EN 61851-21-2
|
|
|
|