Product brief introduction
Thermal flow switch is based on the principle of heat exchange design, probe the built-in heating module as well as the thermal module, heat dissipation of heating module and the flow velocity is closely related to the body. If there is no medium flow in the pipe ,thermal circuit receives a fixed value, when the fluid flows through the probe, thermal circuit receives the signal changes over medium velocity, thermal circuit will convert the temperature difference signals of heating module and thermal module into electrical signals, the processor will convert it into PNP/ NPN/ relay signal output.
Feature
LED indicate the velocity
no moving parts, free maintenance
various length of sensors can be chose
easy to install
various pipes can use only one type of sensor
the set-point can be adjust continuous
almost no pressure loss
protection grade IP67
Water flow sensor technical parameter
Measure range | Water:3~300cm/s ; Oil:3~300cm/s |
Accuracy | ±1~±10cm/s |
Settling time | 3 minutes |
Pressure | 100Bar |
Media temperature | -20 to 80℃ |
Thread | G1/2 ,G1/4 Male thread /M18 Female thread |
Output signal | PNP / NPN / Relay |
Power | 24VDC , 110VAC , 220VAC |
Sensor length | 15mm , 20mm , 30mm , 40mm , 60mm |
Consumption current | <60mA |
Setting | Potentiometer |
Response time | 2(2-10)s |
Max.temperature gradient of medium | 300K/min |
Protect | Reverse / Short / Overload |
Protection grade | Ip67 |
Power connector | M12 connector |
Material | Sensor : 316 Body : 316 |
Load |
Current : 250mA Relay : 30VDC/5A ,110VAC/5A, 220VAC/5A |