b4aaeaa18d46388282116e224b30516a.jpg
2d7ca2ed11e3346e96dcdae1465996e2.jpg
d7d72aecb2fb39528059381cf0999b57.jpg
fe1a92b2e7153823bd6c94c5069f7676.jpg
NaN / 0

3Cx300sq.mm 19/33kV 36kV CU/XLPE/PVC Copper Insulated MV Underground Power Cable for 33/11kV Substation

Get Latest Price
US$ 3.89
≥100 Meters
US$ 2.76
≥2000 Meters
US$ 1.87
≥5000 Meters
US$ 0.6
≥10000 Meters

Quick Details

Insulation Material:
Xlpe
Application:
Underground
Conductor Material:
Copper
Jacket:
PVC
Product Details
3Cx300sq.mm 19/33kV 36kV CU/XLPE/PVC Copper Insulated MV Underground Power Cable for 33/11kV Substation
Product Paramenters
3Cx300sq.mm 19/33kV 36kV CU/XLPE/PVC Copper Insulated MV Underground Power Cable for 33/11kV Substation
3Cx300sq.mm 19/33kV 36kV CU/XLPE/PVC Copper Insulated MV Underground Power Cable for 33/11kV Substation
1.Executive standard GB/T 12706.1-2020
2.Product use The product is suitable for power supply, transmission and distribution lines with rated AC voltage U0/U 26/35kV and below.

3.Features A) during normal operation of cable, the maximum conductor temperature shall be 70℃ for PVC insulation and 90℃ for XLPE insulation.   B) Maximum temperature of conductor during short circuit (maximum duration not exceeding 5 seconds) :   PVC insulation -- 160℃ for conductor cross section ≤300mm2, 140℃ for conductor cross section > 300mm2;  Crosslinked PVC insulation at 250℃.   C) When laying cables, the ambient temperature shall not be less than 0℃, and the minimum allowable bending radius is as follows:   Single core cable: unarmored 20D, armored 15D   Multi-core cable: 15D for unarmored, 12D for armored   Where: D- actual outer diameter of cable.   D) Cable breaking force:   Aluminum core cable: 40×S (N)   Copper core cable: 70×S (N)   Note: S is the total cross-sectional area of the conductor
4.Product model and application
Model
Name
APPLICATION
Copper core
aluminium core

YJV
YJLV
XLPE insulated PVC sheathed
power cable
Can be laid at indoor, tunnel and tube. Cable cannot under take mechanism outside force
YJY
YJLY
XLPE insulated PE sheathed
power cable
Can be laid at indoor, tunnel tube and serious polluted places. Cable cannot undertake mechanism outside force
YJV22
YJLV22
XLPE insulated steel tape armored PVC sheathed power cable
Can be laid at indoor, tunnel tube and mining well. Cable cannot undertake mechanism outside force
YJV23
YJLV23
XLPE insulated steel tape armored PE sheathed power cable
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force
YJV32
YJLV32
XLPE insulated fine steel wire armored PVC sheathed power cable
Can be laid at indoor, underground and mining well. Cable can undertake mechanism outside force
YJV33
YJLV33
XLPE insulated fine steel wire armored PE sheathed power cable
Can be laid at indoor, underground .Cable can under take mechanism outside force
3Cx300sq.mm 19/33kV 36kV CU/XLPE/PVC Copper Insulated MV Underground Power Cable for 33/11kV Substation
Product Details