when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the
testing pattern.
⊗Time-Delay is added continually: When it receives the second induction signals after the first induction, it
will compute time once more on the basic of the first time-delay rest.
⊗Time–Delay is adjustable. It can be set according to the consumer’s desire. The minimum time is
10sec±3sec. The maximum is 8min±2min.
Installation(see the following figure)
⊗Switch off the power.
⊗Turn clockwise the bottom-stand and take off it. The power wire cross the hole in the middle of
bottom-stand.
⊗The bottom-stand is fixed on the selected position with inflated screw.
Connect the power and the load into the connection-wire column of the sensor according to
⊗connection-wire diagram.
⊗The sensor aimed at the mouth of bottom-stand and turned anti-clockwise.
Note
⊗Electrician or experienced human can install it.
⊗The unrest objects can’t be regarded the installation
basis-face.
⊗In front of the detection window there aren’t hinder or unrest
objects effecting detection.
⊗Avoid installing it near air temperature alteration zones for
example: air condition, central heating, etc.
⊗Please don’t open the case for your safety if you find the
hitch after installation.
⊗If there are some difference between instruction and the
function the product has, please give priority to product and
sorry not to inform you additionally.
Some problem and solved way
The load don’t work:
a: Check the power and the load;
b: If the load is good;
c: If the indicator lamp is green;
d: Please check if the working light correspond to the light-control
.
The sensitivity is poor:
a: Please check if in front of the detection window there is hinder that effect to receive the signals;
b: Please check the ambient temperature;
c: Please check if the signals source is in the detection field;
d: Please check the installation height;
e: If the moving orientation is correct.
The sensor can’t shut automatically the load:
a: If there are continual signals in the detection fields;
b: If the time setting is set to the longest;
c: If the power correspond to the instruction;
d: If the air temperature change near the sensor, for example air condition or central heating etc.