Features:
·Output constant voltage
· UL, cUL listed, Class 2, Class P, Type HL
·Universal AC input: 100-277 VAC
· With slightly adjustable output voltage
.Power Factor: up to 0.99
·High efficiency : up to 88 %
·Protection:short circuit/over loading/ Over temperature
·Full protection aluminum housing , for dry, damp location
·Cooling by free air convection
·Suitable for LED lighting and moving sign applications
Specification:
Model |
KV-120 60 - ASW |
KV-240 60 - ASW |
|
Certificates |
FCC UL cUL Class 2 |
FCC UL cUL Class 2 |
|
O utput |
DC Voltage |
12V |
24V |
Adj. Voltage Range |
10-13V |
21.5-25.5V |
|
Rated C urrent |
5 A |
2.5 A |
|
Rated P ower |
60 W |
||
Voltage Tolerance |
±0.5V |
||
Voltage Regulation |
± 0.5% |
||
Load Regulation |
± 1% |
||
I nput |
Voltage Range |
100 -277 VAC |
|
Frequency Range |
47-63 H z |
||
Power Factor ( Typ. )@ full load |
0. 99@120VAC 0.94@230VAC 0. 94@277VAC |
0. 99@120VAC 0.95@230VAC 0. 94@277VAC |
|
THD( Typ. )@ full load |
< 15%@120VAC <20%@230VAC < 20%@277VAC |
||
Efficiency ( Typ. )@ full load |
8 3 % @120VAC 87%@230VAC 85%@277VAC |
8 5 % @120VAC 88%@230VAC 86%@277VAC |
|
AC Current ( Max . ) |
0.9 A @100VAC |
0.9A@100VAC |
|
Inrush Current ( Typ. ) |
14A, 50%, 780us@120VAC; 50A,50%,176us@230VAC; 15A,50%,660us@277VAC |
||
Leakage current |
<0. 5 0mA |
||
Protection |
Short Circuit |
shut down o/p voltage , re-power on to recover after fault condition remove d |
|
Over Loading |
≤120% Hiccup mode,recovers automatically after fault condition is removed |
||
Over temperature |
100℃±10℃ shut down o/p voltage, automatically recover after cooling. |
||
Environment |
Working TEMP. |
-40 ~ + 6 0℃ (see below derating curve) |
|
Working Humidity |
20 ~ 90%RH, non-condensing |
||
Storage TEMP. Humidity |
-40 ~ +80℃ , 10 ~ 95%RH |
||
TEMP .coefficient |
±0.03%/℃ ( 0 ~ 50℃ ) |
||
Vibration |
10 ~ 500Hz , 2 G 10min./1 cycle,period for 60min. each along X,Y,Z axes |
||
Safety& EMC |
Safety standards |
UL8750+UL1310 |
|
Withstand voltage |
I/P-O/P: 1.88 KVAC |
||
Isolation resistance |
I/P-O/P : 100MΩ/500VDC/25℃/70%RH |
||
EMC EMISSION |
FCC Part 15 B |
||
Notes |
1. All parameters if NOT specially mentioned are measured at 1 2 0VAC input , rated load and 25℃of ambient temperature. 2. To extend the driver's using life ,please reduce the loading at lower input voltage. |