Focus On Time Control For 24 Years
Description
- Data read/write memory card
Copying programs and pluse times
Storing programs and pluse times
Current time storing to memory card continue to count
Memory card has a built-in rechargeable battery
- Keypad lock
Press the key after pressing the other key is invalid
Key no action within 30 seconds, automatic lock
Press the clock key 4 times to lock or unlock
- Digital time switch with weekly program and day cycle
- 20 groups on-off program
Can Switching preselection
Can manually to control on-off
- 38 times pulse programs
Adjustable pulse duration 1s~59m59s
- Countdown
Adjustable Countdown duration 1s~99m59s
- 1 channel
- Screw terminals
- Preset date and time
LCD Display
Can manually set Daylight Saving Time(1 Hours)
12/24 hour format conversion
Can auto-correct time(-3 sec ≤t≤3 sec) every day
--- AHC15A-U-xx/xxHz-xP-xxA-H can not be setting
- Built-in lithium battery, and travel time as usual after power failure
Fully operable without mains connection
- Integrated operating hour counter and action times
AHC15A-U-xx/xxHz-xP-xxA-H
Time accuracy at 25 °C: typical ± 2Min/years
Product Selection
Product Type | Voltage | Frequency | Terminal | Switching capacity |
AHC15A-U-220/50Hz-16A | 220V | 50Hz | 5 | 16A |
AHC15A-U-220/60Hz-16A | 220V | 60Hz | 5 | 16A |
AHC15A-U-110/50Hz-16A | 110V | 50Hz | 5 | 16A |
AHC15A-U-110/60Hz-16A | 110V | 60Hz | 5 | 16A |
AHC15A-U-12V-16A | AC/DC 12V | 50/60Hz for AC | 5 | 16A |
AHC15A-U-24V-16A | AC/DC 24V | 50/60Hz for AC | 5 | 16A |
AHC15A-U-220/50Hz-3P-20A | 220V | 50Hz | 3 | 20A |
AHC15A-U-220/50Hz-5P-20A | 220V | 50Hz | 5 | 20A |
AHC15A-U-220/60Hz-3P-20A | 220V | 60Hz | 3 | 20A |
AHC15A-U-220/60Hz-5P-20A | 220V | 60Hz | 5 | 20A |
AHC15A-U-110/50Hz-3P-20A | 110V | 50Hz | 3 | 20A |
AHC15A-U-110/50Hz-5P-20A | 110V | 50Hz | 5 | 20A |
AHC15A-U-110/60Hz-3P-20A | 110V | 60Hz | 3 | 20A |
AHC15A-U-110/60Hz-5P-20A | 110V | 60Hz | 5 | 20A |
AHC15A-U-12V-20A | AC/DC 12V | AC 50/60Hz | 5 | 20A |
AHC15A-U-24V-20A | AC/DC 24V | AC 50/60Hz | 5 | 20A |
Technical Data:
(1) 16A Loading
Times of switch setting | 20 groups |
pulse programs | 38 times |
pulse time | 1s~59m59s |
Count down | 1s~99m59s |
Width | 2 modules |
Installation type | Din rail |
Terminal Quantity | 5 |
Type of contact | Changeover contact |
Switching output | Phase-independent |
Method of connection terminal | Screw terminals |
Power reserve | 3 years |
Switching capacity at
250 V AC, cos φ = 1 |
16A |
Switching capacity at
250 V AC, cos φ = 0,6 |
10A |
Incandescent/halogen lamp load 230V | 2600W |
Energy saving lamps | 170W |
LED lamp < 2 W | 30W |
LED lamp 2–8 W | 100W |
LED lamp > 8 W | 120W |
Fluorescent lamp load (electronic ballast) | 650W |
Fluorescent lamp load (conventional)
|
1000VA |
Fluorescent lamp load (conventional)
series-corrected |
1000VA |
Fluorescent lamp load (conventional)
parallel-corrected |
730 VA 80uF |
Time accuracy at 25 °C | typical ± 2 s/day (quartz) |
Consumed power | 4VA |
Test approval | CE |
Type of protection | IP 20 |
Protection class | II according to EN 60 730-1 |
Housing and insulation material | High-temperature resistant, self-extinguishing thermoplastic |
Work temperature | -10 ~ +50 °C (non-icing) |
Ambient humidity | 35~85%RH |
(2) 20A Loading
Times of switch setting | 20 groups |
pulse programs | 38 times |
pulse time | 1s~59m59s |
Count down | 1s~99m59s |
Width | 2 modules |
Installation type | Din rail |
Type of contact | Changeover contact |
Switching output | Phase-independent |
Method of connection terminal |
Screw terminals |
Power reserve | 3 years |
Switching capacity at
250 V AC, cos φ = 1 |
20A |
Switching capacity at
250 V AC, cos φ = 0,6 |
12A |
Incandescent/halogen lamp load 230V |
3200W |
Energy saving lamps | 200W |
LED lamp < 2 W | 36W |
LED lamp 2–8 W | 120W |
LED lamp > 8 W | 150W |
Fluorescent lamp load (electronic ballast) |
800W |
Fluorescent lamp load (conventional) not corrected |
1200VA |
Fluorescent lamp load (conventional)
|
1200VA |
Fluorescent lamp load (conventional)
|
900 VA 80uF |
Time accuracy at 25 °C | typical ± 2 s/day (quartz) |
Consumed power | 7VA |
Test approval | CE |
Type of protection | IP 20 |
Protection class | II according to EN 60 730-1 |
Housing and insulation material |
High-temperature resistant, self-extinguishing thermoplastic |
Work temperature | -10 ~ +50 °C (non-icing) |
Ambient humidity | 35~85%RH |
Connection Diagrams And External Dimension
(1) 16A Loading
(2) 20A Loading
- AHC15A-xxx/xxHz-5P-20A-USB