SPECIFICATIONS
|
|
|
|
|
|
|
|
|
||||||||
Model
|
S-350-5
|
S-350-7.5
|
S-350-12
|
S-350-13.5
|
S-350-15
|
S-350-24
|
S-350-27
|
S-350-48
|
||||||||
DC Voltage
|
5V
|
7.5V
|
12V
|
13.5V
|
15V
|
24V
|
27V
|
48V
|
||||||||
Rated Current
|
50A
|
40A
|
30A
|
25.8A
|
23.2A
|
14.6A
|
13A
|
7.3A
|
||||||||
Current Range
|
0-50A
|
0-40A
|
0-30A
|
0-25.8A
|
0-23.2A
|
14.6A
|
13A
|
0-7.3A
|
||||||||
Rated Power
|
200W
|
198.7W
|
198W
|
198.45W
|
198W
|
199.2W
|
199.8W
|
201.6W
|
||||||||
Ripple & Noise
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
240mVp-p
|
||||||||
Voltage Adj. Range
|
±10%
|
-12%;+15%
|
-12%;+10%
|
-12%;+11%
|
±10%
|
-12%;+16%
|
-12%;+11%
|
±10%
|
||||||||
Voltage Tolerance
|
±2%
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
||||||||
Voltage Range
|
88~132VAC/176~264VAC selected by switch 47~63Hz; 248~370VDC
|
|
|
|
|
|
|
|
||||||||
AC Current
|
3.2A/115V 1.6A/230V
|
|
|
|
|
|
|
|
||||||||
Efficiency
|
73%
|
76%
|
74%
|
79%
|
78%
|
81%
|
82%
|
83%
|
||||||||
Inrush Current
|
Cold start 35A/230VAC
|
|
|
|
|
|
|
|
||||||||
Leakage Current
|
<3.5mA/240VAC
|
|
|
|
|
|
|
|
||||||||
Over Load
|
110%~160%
|
|
|
|
|
|
|
|
||||||||
|
Protection type: Shut down o/p voltage, re-power on to recover
|
|
|
|
|
|
|
|
||||||||
Over Voltage
|
115%~135%
|
|
|
|
|
|
|
|
||||||||
|
Protection type: Shut down o/p voltage, re-power on to recover
|
|
|
|
|
|
|
|
||||||||
Working Temp., Humidity
|
-10℃~+60℃; 20%~90%RH
|
|
|
|
|
|
|
|
||||||||
Storage Temp., Humidity
|
-20℃~+85℃; 10%~95%RH
|
|
|
|
|
|
|
|
||||||||
Vibration
|
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
|
|
|
|
|
|
|
|
||||||||
Safety Standard
|
Design refer to UL1012, UL1950, TUV EN60950
|
|
|
|
|
|
|
|
||||||||
EMC Standard
|
Design refer to EN55022, EN61000-3-2, -3, EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024
|
|
|
|
|
|
|
|
||||||||
Warranty
|
2 years
|
|
|
|
|
|
|
|