Measuring Medium
|
Liquid, Gas or Steam
|
Pressure Range
|
-100kPa~40MPa
|
Output Signal
|
4~20mADC with HART
|
Permissible Load Resistance
|
0~600Ω(DC 24V)
|
Supply Voltage
|
10.5~45VDC (General Service),
10.5~26VDC (Intrinsic safety and explosion-proof) |
Zero-scale Migration
|
Within between -20% ~ 20% of maximum range
|
Output Mode
|
Linear output, square root output
|
Ambient Temperature
|
-40~85℃ (when fluorocarbon oil filled:-10~60℃)
|
Storage Temperature
|
-40~90℃
|
Accuracy
|
TD 1:1…15:1 =±0.075%
TD>15:1 =±(0.0015×TD+0.053) % |
Overpressure Influence
|
±0.05% of maximum range/10MPa
|
Stability
|
±0.05% of maximum range /12 months
|
Protection of Shell
|
IP66
|