Range
|
-0.1MPa...0kPa~10kPa...100MPa
|
|
|
||
Fluid material
|
Standard: 316L stainless steel ceramics, typical: khashi alloy or gold plated diaphragm
|
|
|
||
Display range
|
-1999~9999
|
|
|
||
Accuracy
|
0.1% (custom), 0.25% (typical), 0.5% (maximum)
|
|
|
||
Temperature Drift
|
≤±0.05%FS/°C (temperature range -20~85°C)
|
|
|
||
Zero point
|
≤±0.02%FS/°C (Typical), ≤±0.04%FS/°C (Max)
|
|
|
||
Full point
|
≤±0.02%FS/°C (Typical), ≤±0.04%FS/°C (Max)
|
|
|
||
Compensation temperature
|
0°C~50°C(≤100kPa), -10°C~70°C(>100kPa)
|
|
|
||
Heat return difference
|
≤±0.5%FS
|
|
|
||
Filling flfluid
|
1. Silicone oil 2.Synthetic oil or sanitary oil
|
|
|
||
Response time
|
Current output max. 2ms, Voltage output max. 10ms
|
|
|
||
Storage temperature
|
-40°C~125°C
|
|
|
||
Medium temperature
|
-30°C~300°C
|
|
|
||
Mechanical impact
|
100g/1ms
|
|
|
||
Mechanical vibration
|
Max. 20g: 15~2000Hz
|
|
|
||
Power supply
|
12 ~ 36VDC (Power consumption of 30mA)
|
|
|
||
Output Signal
|
Analog output: 4mA~20mA (superimposable HART protocol).0V~10V
Digital output: RS485 Control output: Switch: 2 way, analog quantity: 1 way |
|
|
||
Load error
|
< 0.5%
|
|
|
||
Protection leve
|
IP65/IP67
|
|
|