meanwell led driver power/ 5v led driver circuit/ led power driver 100w
MODEL |
LRS-100-5 |
LRS-100-12 |
LRS-100-24 |
|
OUTPUT |
DC VOLTAGE |
5V |
12V |
24V |
RATED CURRENT |
18A |
8.5A |
4.5A |
|
CURRENT RANGE |
0 ~ 18A |
0 ~ 8.5A |
0 ~ 4.5A |
|
RATED POWER |
90W |
102W |
108W |
|
SETUP, RISE TIME |
500ms, 30ms/230VAC 500ms,30ms/115VAC at full load |
|||
HOLD UP TIME |
55ms/230VAC 10ms/115VAC at full load |
|||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) |
||
FREQUENCY RANGE |
47 ~ 63Hz |
|||
INRUSH CURRENT |
COLD START 50A/230VAC |
|||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70 ℃ (Refer to " Derating Curve") |
||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
|||
OTHERS |
DIMENSION |
129*97*30mm (L*W*H) |
||
PACKING |
0.34Kg ; 40pcs/14.6Kg/0.92C |
Features :
Universal AC input /
Full range
Withstand 300VAC surge input for 5 second
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Miniature size and 1U low profile
Compliance to IEC/EN 60335-1(PD3) and
IEC/EN61558-1, 2-16 for household appliances
Operating altitude up to 5000 meters (Note.7)
Withstand 5G vibration test
LED indicator for power on
No load power consumption<0.3W
100% full load burn-in test
High operating temperature up to 70℃
High efficiency, long life and high reliability
3 years warranty
LRS-100 series is a 100W single-output enclosed type power supply with 30mm of low profile design.
Adopting the full range 85~264VAC input, the entire series provides an output voltage line
of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat
dissipation of LRS-100 that the whole series operates from -30 ℃ through 70 ℃ under air
convection without a fan. Delivering an extremely low no load power consumption (less
than 0.3W), it allows the end system to easily meet the worldwide energy requirement.
LRS-100 has the complete protection functions and 5G anti- vibration capability ; it is
complied with the international safety regulations such as TUV EN60950-1, EN60335-1,
EN61558-1/-2-16, UL60950-1 and GB4943. LRS-100 series serves as a high price-to-
performance power supply solution for various industrial applications.
Industrial automation machinery
Industrial control system
Mechanical and electrical equipment
Electronic instruments, equipments or apparatus
Household appliances
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ℃ of
ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with
a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly
may lead to increase of the set up time.
7. The ambient temperature derating of 5 ℃ /1000m is needed for operating altitude greater than
2000m(6500ft).
8. The power supply is considered a component which will be installed into a final equipment. The final
equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to “ EMI testing of component power supplies. ”