Power supply: 220VAC 50HZ /
110VAC 60HZ
Motor's power: 90W 220VAC
Max length of boom: 6m
Time for up/down: 3S( for 1~3m),6S( for 4~6m)
Environment temperature: -20
o
C-50
o
C
Protection class: IP55
Power supply: 220VAC 50HZ
/
110VAC 60HZ
Motor's power: 80W 24VDC
Max length of boom: 6m
Time for up/down: 3S( for 1~3m),6S( for 4~6m)
Environment temperature: -20
o
C-50
o
C
Protection class: IP55
Features :
1.- The traffic barrier is widely used for the facilities of parking, traffic or toll system.
2.-Arms can be chosen from 3 meters to 6 meters.
3.-This type of barrier could match with direct boom( pole), fold boom Or fence boom..
4.-Advanced manual release .Clutch key can be used to open the clutch when electricity is cut off.
5.-All the process is soft without any noise and shaking.
6.-This barrier gate has many input terminals for photocell, Airwave switch, loop detector, back-up battery(for DC Motor), toll gate system and output terminals for lamp.
7.-Housing color: yellow,red ,blue,orange,white (optional)
8.-Boom arm direction can be chosen leftward to rightward.
9.-Auto warming up,suitable for cold environment.
10-Controlling way :wireless or wiring multiple push button for OPEN,CLOSE,STOP function.
BS-106, BS-206, BS-306,
BS-406, BS-606, BS-806,
BS-3306, BS- 6306, BS-6706
Number
|
Trouble
|
Cause
|
Shooting
|
1
|
Motor of Barrier does not work
|
1,No power supply
|
1,Check power supply
|
|
|
2,Break fuse
|
2,Change fuse
|
|
|
3,Motor is damaged
|
3,Change the motor
|
2
|
Barrier can open but can not close
|
1,Photocell is not connected properly
|
1,Connect the photocell
|
|
|
2,Photocell beam is block off
|
2,Clear out obstacle
|
|
|
3,Photocell is broken
|
3,Change a new device
|
3
|
Barrier can open (close) but can not close (open)
|
1,Position of limit switch is not correct
|
1,Adjust position
|
|
|
2,Limit switch is damaged
|
2,Change limit switch
|
4
|
Barrier can not locate accurately
|
1,Distance of limit switch is too large
|
1,Adjust position of limit switch
|
|
|
2,Limit switch is wrong
|
2,Change limit switch
|
|
|
3,Magnetic-stell’s position is wrong
|
3,Re-adjust the position
|
5
|
Release device of Barrier is doesn’t work
|
1,Operating handle is broken
|
1,Change the handle
|
|
|
2,Worm gears are jammed
|
2,Rotate the pinion
|
6
|
Push the “OPEN” button but the Barrier gate close
|
Whether “+MOTOR-” wires are connected wrong
|
Connect correctly according to wiring diagram
|
7
|
Motor of Barrier can work but boom can not work
|
Compression spring of clutch is dead
|
Change the spring
|