8020Ni-Cr alloy finned resistor
Each resistance element: insulation impedance DC2000V/10MΩ above
Withstand voltage AC2000v for 1 min;
Resistance error of each resistance tube: ±2%
Can stable work under 350ºC
.
Load control :
Manually control
Loading accuracy :
≤ 3% or
customized
3 phase balance :
unbalance degree: ≤3%
Working mode(Duty cycle) :
continuous work
Load protection :
short circuit,over current,high temperature,fan fault protection,emergency stop
Work voltage
:
AC380V/50Hz,3 phase 4 wire
Cooling mode :
forced air cooling, horizontal air inlet/out let
Insulation class :
F
Protection grade :
IP23(when user)
Measurement accuracy :
the display accuracy is 0.5,the sampling accuracy is 0.2
Electrical parameter display :
3 phase voltage, 3 phase current, frequency, power,power factor
Load expansion :
parallel expansion of multiple loads
Standard :
meet international standard,ship standard and telecommunication standard
Transport :
load-bearing lifting hole,castors or forklift hole can be selected.
Color :
RAL6018/RAL7035/customized
Ambient temperature :
-20ºC to 50ºC
Humidity :
up to 100%
Altitude :
up to 2500m
Atmospheric pressure :
86 to 106kPa
Dimensions(L*W*H) :
2120*1520*2180mm
Weight :
1800Kg