Linearity |
0.5% |
Repeatability |
0.20% |
Accuracy |
Better than ±1% for velocity above 0.2m/s |
Response Time |
0-999 second, user-configurable |
Flow Range |
±32m/s |
Measuring Pipe Size |
25mm-6000mm |
Units |
English (U.S.) or metric |
Totalizer |
7-digit totalizer for net, positive and negative flow respectively |
Liquid Types |
Any single uniform liquid which can transmit ultrasonic |
Security |
Setup values Modification Lockout. Access code needs unlocking |
Display |
4×16 character |
Communication |
RS-232 interface. 75-57600bps, compatible with Fuji ultrasonic flowmeter and other UFM on enquiry. |
Interface |
|
Transducers |
Model M1 for standard, other 4 models for optional |
Transducer Cable |
Standard 5m x2 or can be extended to 10m x2 |
Power Supply |
3 AAA built-in Ni-MH batteries (for over 12 hours of operation). 100V-240VAC adapter |
Data Logger |
Built-in data logger can store over 2000 lines of data |
Manual Totalizer |
7 digit, calibrating by key |
Housing Material |
Flaming retarding ABS |
Size |
200×93×33mm |
Handset Weight |
400g with batteries |