fac314b7b08637e7993b2bb67b7bb8fa.jpg
81458dfa963c3d6986fbc06cd41b7d87.jpg
02e0c3d93ebe3aa484539d075966f4d9.jpg
6c68eb034ff135c6a86d504877b0dc53.jpg
NaN / 0

Good Quality Water Level Float Switch Cable Type Liquid Fluid Water Level Controller Sensor 2m float switch

Get Latest Price
US$ 17.5
≥20 Pieces
US$ 16
≥100 Pieces
US$ 12
≥500 Pieces
US$ 7.7
≥1000 Pieces

Quick Details

Media Type:
Liquid
Place of Origin:
Jiangsu, China
Brand Name:
Baijia
Model Number:
F45,FC45
Product Details
Good Quality Water Level Float Switch Cable Type Liquid Fluid Water Level Controller Sensor 2m float switch
Product Description
Good Quality Water Level Float Switch Cable Type Liquid Fluid Water Level Controller Sensor 2m float switch
Good Quality Water Level Float Switch Cable Type Liquid Fluid Water Level Controller Sensor 2m float switch
Good Quality Water Level Float Switch Cable Type Liquid Fluid Water Level Controller Sensor 2m float switch

Product feature

1. When mechanical rolling steel ball, Omron microswitch control.
2. Float product internal upgrade three times seal,360 barrier-free work.
3. The cable core is strengthened with waterproof treatment to prevent water and gas from entering the float ball through the cable to fully meet the requirements of leakage and moisture proof to ensure the electrical safety of the float ball.
4. Waterproof nut type weight design can be arbitrarily hung above the detection point and can be adjusted according to the monitoring point without any accessories can be arbitrarily adjusted height, easier installation.
5 Suitable for long distance can control the liquid level of 20cm-200cm can be used.
6. The structure has strong water resistance and pollution resistance, reliable and long life. 7 For water supply and drainage and corrosive liquid level automatic control, warranty 2 years (artificial or self-cut cable, not free replacement.

Use
CT-AR/CT-AY/CT-AB/CT-Ss/CT-SL series cable float level switch uses the buoyancy of the liquid to automatically turn over the internal contact with the liquid level rising or falling, and the state of the switch occurs on and off, and sends out a control signal; Can adapt to different application requirements, such as sewage lifting device, sewage pump, water tank, water tower, fire pool, sewage treatment plant, pumping station and other untreated, containing suspended sewage, waste water and other applications.


Weight mounting method:
1. Pass the cable through the waterproof nut to the position you need to tighten the waterproof nut, and the heavy hammer will not slip.
2. The weight is attached only on request.
3. The final interface parts of the cable should not be immersed in water during installation.


Heavy hammer product features:
1. It is recommended to use silicone cables for sewage in the specified voltage, current and temperature range. 2. The distance between the general liquid level float switch and the fixed (positioning) part shall not be less than 15CM. 3 Multiple sets of cable float level switches can also be used to control the water pump in series to prevent the cable float level switch from working improperly and damaging the equipment.


About the contactor:
When the single power is greater than the floating ball bearing power, it is necessary to use contactor. The selection of
contactor can be based on the power of the motor.


The reference selection of contactors is as follows:
CJX2-0910CJX2-1210 CJX2-1810 CJX2-2510CJX2-3210
Single-phase 0-1KW1-1.5KW1.5-2KW2-3KW3-5KW Three phase 0-2KW2-3KW3-5.5kW5-5.7.5KW7.5-11kW

Precautions and prohibited operations
1, the specified voltage and current and temperature range of use, sewage and other recommended to use silicone cable
2, universal liquid level float switch installation distance: float switch and fixed (positioning) part of the distance shall not
be less than 15CM.
3. Multiple sets of cable float level switches can also be used to control the water pump in series to prevent the cable float level switch from working improperly and damaging the equipment.
4, the power cord is a complete part of the device, once found damaged wire, the device should be replaced, not allowed to repair the cable.
5, please connect the cable directly to the distribution control box, try to avoid the middle connector, if there is a connector
must not be immersed in water cable connector.
6, when wiring, pay attention to the point, when wiring in the wiring pipe slot, do not pull the cable, hard pulling will lead to
cable copper wire pulled off, the signal is good or bad 4 water pump must be grounded and equipped with a suitable leakage switch to ensure personal safety
7. Keep the unused cable insulated
Product specifications
Model
Cable material
Micro switch
Wire length
MOQ>1
($)
MOQ>50
($)
MOQ>100
($)
F45-2X5A*2m
Rubber wire 2 core
Omron
2 meters
8.5
7.5
6.5
F45-2X5A*3m
Rubber wire 2 core
Omron
3 meters
9.5
8.5
7.5
F45-2X5A*4m
Rubber wire 2 core
Omron
Four meters
10.5
9.5
8.5
F45-2X5A*5m
Rubber wire 2 core
Omron
5 meters
11.5
10.5
9.5
F45-2X5A*10m
Rubber wire 2 core
Omron
10 meters
15.5
14.5
13.5
F45-2X5A*15m
Rubber wire 2 core
Omron
15 meters
19.5
18.5
17.5
F45-2X5A*20m
Rubber wire 2 core
Omron
20 meters
23.5
22.5
21.5
FC45-3X5A*2m
Rubber wire 3 core
Omron
2 meters
9.5
8.5
7.5
FC45-3X5A*3m
Rubber wire 3 core
Omron
3 meters
10.5
9.5
8.5
FC45-3X5A*4m
Rubber wire 3 core
Omron
4 meters
11.5
10.5
9.5
FC45-3X5A*5m
Rubber wire 3 core
Omron
5 meters
12.5
11.5
10.5
FC45-3X5A*10m
Rubber wire 3 core
Omron
10 meters
16.5
15.5
14.5
FC45-3X5A*15m
Rubber wire 3 core
Omron
15 meters
23.5
22.5
21.5
FC45-3X5A*20m
Rubber wire 3 core
Omron
20 meters
29.5
28.5
27.5
F45-2G5A*2m
Silicone wire 2 core
Omron
2 meters
9.5
8.5
7.5
F45-2G5A*3m
Silicone wire 2 core
Omron
3 meters
10.5
9.5
8.5
F45-2G5A*4m
Silicone wire 2 core
Omron
4 meters
12
11
10
F45-2G5A*5m
Silicone wire 2 core
Omron
5 meters
12.5
11.5
10.5
F45-2G5A*10m
Silicone wire 2 core
Omron
10 meters
18.5
17.5
16.5
F45-2G5A*15m
Silicone wire 2 core
Omron
15 meters
24.5
23.5
22.5
F45-2G5A*20m
Silicone wire 2 core
Omron
20 meters
29.5
28.5
27.5
FC45-3G5A*2m
Silicone wire 3 core
Omron
2 meters
10.5
9.5
8.5
FC45-3G5A*3m
Silicone wire 3 core
Omron
3 meters
12.5
11.5
10.5
FC45-3G5A*4m
Silicone wire 3 core
Omron
4 meters
14.5
13.5
12.5
FC45-3G5A*5m
Silicone wire 3 core
Omron
5 meters
15.5
14.5
13.5
FC45-3G5A*10m
Silicone wire 3 core
Omron
10 meters
24.5
23.5
22.5
FC45-3G5A*15m
Silicone wire 3 core
Omron
15 meters
32.5
31.5
30.5
FC45-3G5A*20m
Silicone wire 3 core
Omron
20 meters
40.5
39.5
38.5
* If you want more details, please contact me
Specification
item
value
Product name
Cable float level switch
Place of Origin
Jiangsu,China
Brand Name
Baijia
Switch selectable
Microswitch/Mercury switch
Domestic micro switch/Omron micro switch
Butadiene rubber wire
Used for water tank, water tower, fire pool and other water supply reservoir cable material selection
Silicone wire
For sewage area
Agility spirit
Universal liquid level float switch up and down Angle 45The upper and lower Angle of the liquid level switch for sewage is 15