Magnetic Float level Gauge
Product description:
This series meters are widely used in the liquid level measurement and control of electricity, petroleum, chemical industry, metallurgy, environment protection, ship building, civil construction, food and other industries .
Technical parameter:
Measure Range: |
150~8000mm (center distance) or on request. |
Nominal Pressure: |
PN6.4MPa Class 400LB ANSI |
Working Pressure: |
≤4.8Mpa 300LB |
Working Temperature |
450°C 723.15K |
Medium Density |
500~2000kg/m³ |
Chamber(bypass tube) |
Φ63.5×3mm |
Process Connection |
Factort y Standard: DN25 PN 6.4MPa HG20592-97;400LB 1" ANSI B16.5 ;
Optional std: 1/2"~ 4" ANSI B16.5; DN10-DN100 GB/T 9112-2000; JB/T 79.1-94 SH3406-1996 DIN 2635;DN10-DN100; DIN 2527;DN10-DN100 10A~100A JIS 30K FF RF; 1/2"~4" JPI 400LB RF |
Chamber/Flange/ Wetted Material |
304, 316, 316L, 316Ti, 321, 1.4301, 1.4435, 1.4401, 1.4571, 1.4783, 0Cr18Ni9, 1Cr18Ni9Ti, 00Cr17Ni14Mo2, 0Cr17Ni12Mo2, 0Cr18Ni2Mo2Ti |
Magnetic Float |
Its size depends on liquid density Materia l: Titanium, 316SS or 316L SS |
Optional Items |
1 Tri-magnet level switch 2 Quad-magnet level switch 3 Heating Jacket 4 Depth Vacuum heating jacket 5 Coil type heating jacket 6 Drain/Vent valves 7 Transmitter(4~20mA, two/ three wire,HART) Magnetostrictive level transmitter |
Product Type
Model type:
UHZ |
|
With blind flange, no drain valve |
|||||||||
|
L |
Bottom drain valve |
|||||||||
|
G |
Tri-magnet driven level switch |
|||||||||
GH |
High temperature four-magnet driven level switch |
||||||||||
|
|
Control points(quantity of level switches) |
|||||||||
|
R |
Ltransmitter two wire 4~20mA output |
|||||||||
R1 |
LB transmitter HART two-wire 4~20mA output |
||||||||||
R2 |
AT200 Magnetostrictive transmitter two-wire 4~20mA output HART |
||||||||||
R3 |
AT201 Magnetostrictive transmitter three-wire 4~20mA output HART |
||||||||||
R4 |
AT202 High temperature magnetostrictive transmitter output HART |
||||||||||
R5 |
AT203 High temperature transmitter three-wire output HART |
||||||||||
|
D |
ExdIIBT1~T6 Explosion proof |
|||||||||
E |
ExiaIICT1~T6 Intrinsically safe |
||||||||||
EF |
Intrinsically safe with barrier |
W |
Wide rollers board |
||||||||
|
|
Removable heating jacket |
J2 |
Sleeve type heating jacket |
|||||||
J3 |
Coil type heat tracing device |
J4 |
Depth vacuum jacket |
||||||||
J5 |
Depth vacuum insulation& compound heating jacket |
||||||||||
|
|
Installation height(N/A for side-side mounted level gauge |
|||||||||
|
|
(M)Measuring range,mm |
|||||||||
|
|
Medium density,kg/m3 |
|||||||||
|
Nominal pressure
|
Installation
How about our service?
trademanager online service:8:00AM~10:00PM, Monday ~ Sunday
skype ID:cindy1987910
telephone:+86 15053538672
warranty:12months