Factory Price ATS Automatic Change Over Switch 100A Automatic Transfer Switch ATS for Diesel Generator

Get Latest Price
US$ 46
≥5 Pieces

Quick Details

Type:
PC
Number of Pole:
4
Place of Origin:
Zhejiang
Brand Name:
SHPK
Product Details
Product Description

Generator transfer switch sources are different and independent. After one power supply is cut off, the second power supply will not be cut off at the same time, which can meet the supply of primary and secondary loads. Dual circuit generally refers to the end, after one line fault, another standby circuit is put into operation to supply power to the equipment. The two loops may be the same power supply or different power supply.

The Precautions For The Installation And Use Of The Load Transfer Switch Are As Follows:

1) When the switch is installed, the handle should be kept in a horizontal rotation position.

2) Because of the low on-off capability of the load transfer switch, it can not be used to break the fault current. When the motor is used for positive and negative rotation control, the power supply can only be connected after the motor completely stops turning.

3) When the load power factor is low, the contact capacity of the switch should be reduced.

The dual power transfer switch is a switch for switching the function of the main circuit and the standby circuit. When the main circuit is de-energized, the dual power switch will automatically switch to the standby circuit (usually an alternator) to ensure the normal use of the electrical appliances in the circuit.

The PKQ2 dual power transfer switch also features an isolation function that provides significant breakpoints during circuit maintenance to prevent the risk of electric shock

Generator transfer switch Suitable for AC 50HZ, rated voltage 400V/690V, rated current 3200A. 3 poles & 4 poles, It is widely used in power generation system.

3-poles or 4-poles

Avoid erroneous operations

Designed according to IEC/ EN 60974-3

Conventional Current 250A 630A 1600A 3150A
Rated Current In (A) 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150
Rated Insulation Voltage Ui (V) 1000
Dielectric Strength (V) 8000 10000
Rated Surge-Resistant Voltage Uimp KV
Rated Working Current AC-21B 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150
380V AC-22B 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150
AC-23B 200 250 315 400 500 630
AC-21B 200 250 315 400 1000 1000 1600 2000 2500 2500
690V AC-22B 160 160 315 315 315 315 800 800 800 1000 1250 1600
AC-23B 100 125
Motor Power 380V 100 132 160 220 280 315 560 560 560 710 710 710
P (Kw) 660V 90 110 185 185 185 185 475 475 475 750 750 750
Rated Short-Time Withstand Current Lcw (KA Rms) 0.1s/1s 12 12 25 25 25 25 50 50 50 50 50 50
Rated Breaking Capability Icn (A Rms) AC23 380V 1600 1600 2520 3200 4000 5040 3000 3750 4800 6000 7500 9450
Rated Making Capability Icm (A Rms) AC23 380V 2000 2500 3150 4000 5000 6300 3000 3750 4800 6000 7500 9450
Rated Shortcurrent Making CapabilityIcm (KA Peak Value) 17 17 40 40 40 40 70 70 70 105 105 105
Mechanical Durability 380V 1400 1400 800 800 800 800 500 500 500 300 300 300
Electical Curability 380V 200 200 200 200 200 200 100 100 100 100 100 100
Operation Moment (Nm) 10 10 14.5 14.5 14.5 14.5 37 37 60 60 60 60
Weight (Kg) 3 Poles 2.2 2.2 4.3 4.3 4.7 4.7 10.5 10.5 16 25.5 25.5 31
4 Poles 2.6 2.6 5.4 5.4 6 6 13 13 20 37.5 37.5 51.5