1. Specification
model |
output voltage |
Current |
power |
Tol. |
R&N |
Effi. |
SMT-012-026VP |
12V |
2A |
24W |
±3% |
80mV |
>82% |
SMT-024-026VP |
24V |
1A |
24W |
±2% |
180mV |
>82% |
2. INPUT REQUIREMENTS
2.1 Operating range: 90-264VAC
2.2 Rated Input Voltage :100-240VAC
2.3 Input Frequency Range: 50/60Hz +/-3Hz
2.4 Input Current: 0.2A max
3.OUTPUT REQUIREMENTS
3.1 Output Voltage and Current
Output |
Output Regulation(V) |
Harf Load |
Rating Load (A) |
|
Voltage(V) |
Minimum |
Maximum |
Current(A) |
Continuous Current(A) |
24V |
23.4V |
24.6V |
0A |
1.0A |
3.2 Output Voltage Regulation
The total output voltage regulation shall be +/-5%,including the effects of line voltage
variations,load current,ripple and noise,and the AC component of the load current.
3.3 Output Voltage Ripple
The switching power supply shall not exceed the following limits in the indicated
voltage for 60Hz or 50Hz ripple,switching frequency ripple and noise measured with
20MHz width.
Ripple and Noise:50/60Hz Ripple + Switching Ripple and Noise
Output |
Ripple |
0 -1 .0 A |
2 00mV |
4. EFFICIENCY
When 230VAC line input voltage (100-240 VAC),the efficiency shall be >79% at rating
load.
5. DIELECTRIC STRENGTH (Hi-Pot) TEST
Finished product withstands with AC 3000Vrms/50Hz,5mA max,
primary to secondary, 1 minute for type test,1 second for production test.
6. INSULATION RESISTANCE
Primary to secondary: 10M Ω min at 500VDC.
7. PROTECTION
7.1 Short Circuit Protection
If short circuit occurs,all the output should be protected. After the fault, the adapter automatically
recovers.
7.2 Over Shoot
The Output over shoot at turn-on shall not exceed 10% of normal voltage value with
or without the load connected.
7.3 Start-up time
The start-up time is less than 2 second.
8.ENVIRONMENTAL CONDITIONS
8.1 Temperature
Operating temperature: 0℃ to +40℃
Storage temperature : -20℃ to +60℃
8.2 Humidity
Relative humidity:≤95%
8.3 Operating Ambient Altitude
Altitude:0-3000m
8.4 Operating at the lower temperature
At -0℃,with the rated voltage 100-240Vac charged to the primary and unloaded and
full load on the secondary 8 hours, no abnormality in electric and mechanical
characteristic, after 2 hours recovery at the room temperature.
8.5 Operating at the high temperature
At +40℃,with the rated voltage 100-240Vac charged to the primary and unloaded
and full Load on the secondary 8 hours, no abnormality in electric and mechanical
characteristic, after 2 hours recovery at the room temperature.
9. COOLING
Cooling shall be with natural convection cooling.
10.Burn-in
The burn-in test will be performed at least 4 hours at centigrade
degrees under full load Condition.
11.Referenced standard
11.1 EMI Standards
Reference EN50082-1,EN55022-B,GB-17625.1-2003, GB-9254-1998
11.2 Safety Standards
The adapter shall be meet certified with the following safety standards.
EN60950-1,GB4943-2001
12. MOUNTING CONNECTORS
12.1 AC Input Connector
Spec :2Pin (CE PLUG)
12.2 DC Output Cable
Wire : (Optional) 24AWG*2C L=1200mm Color: Black
Plug : (Optional) 5.5 x 2.1x 10mm Turning fork line
13. MECHANICAL FEATURES
13.1 Dimension(Size)
Length: 59.8mm
Width: 38.8mm
Height: 45mm
13.3 Vibration and shock
No Evidence of any mechanical or functional damage after the vibration and shock
testing.
Test conditions |
Acceptance Criteria |
|
Frequency |
10-55Hz |
Nominal functional test should be satisfied after the test |
Sweep |
For each axis(X,Y,Z) |
|
Displacement |
0.15mm |
|
Periodicity |
10 |
14 . DIAGRAM DATA:( See to attach the diagram)
14.1. APPEARANCE DRAWING:(Unit:mm)
14.3. DIMENSION OF OUTPUT PLUG & DC CORD:(Unit:mm)
Remarks
1) 24AWG*2C L=1200mm Color: Black
2) PLUG:5.5 x 2.1 x 10mm Turning fork line
What kind of LED Driver/Power Supply Smarts Electronics do?