Name of Test
As Per IS 2556 (Part) 1994
Vistaar Overseas Value
Water Absorption
Average value should not exceed more than 0.5 %
Max 0.30 % show better vitrification.

Crazing Test
No crazing up to 2 cycle up 5 hrs each cycle or 10 hrs at pressure 0.34 to 0.37 Mps.
No problem up to 4 cycle and no crazing.
Chemical Resistance
No loss of reflectivity of the glaze when compared with control sample.
No loss of reflectivity of the glaze when compared with control sample.
Modules of Repture
Not less than 60 Mpa.
Minimum 65 Mpa. / Minimum 80 Mpa.
Resistance to Staining and Burning
No stain shall remain on either of test piece.
No stain shall remain on either of test piece.
Discoloration
None on all visible surface.
None on all visible surface.
Wavy Finish
None on all visible surface.
None on all visible surface.
Note : All products dimension may vary 10 % to 15 % from the dimension given in the catalogue.
Trouble Shooting Guide
PRODUCT
PROBLEM
PROBABLE REASONS
CORRECTIVE ACTIONS



One Piece Water Closet
Water not coming in Bowl area while flushing.
Mechanism inside tank may not be working properly.
Change the center pump of mechanism.
Water is continuously leaking Inside the Bowl.
There is no water in tank.
Increase the ball cock height to the maximum level.
Water Quantity insufficient for effective Flushing.
Mechanism inside tank may not be working properly.
Change the center pump of mechanism.
Uneven flow of water from both side of Closet.
Ball Cock height adjusted at lower level.
Increase the ball cock height to the maximum level.



Wash Basins / Table Top
Overflow chocked and foul bad odour.
Waste coupling used may be full threaded.
Waste coupling should be replaced by slot cut coupling.
Water deposit on tap platform area and inside.
Basin is not flued in level or bracket is not in level.
Should be done by proper leveling.
There is no tap hole in Basin.
Tap hole can be semi punched from back side.
Tap Hole should be created by plumber from semi punched area.


EWC / Pan / Anglo Indian


Water not coming in Bowl area while Flushing.

Flush bend is not inserted up to the end of inlet hole.
Insert the flush pipe up to the end of inlet for Pan / Closet check whether flush pipe is not covering flush hole which is in both side of inlet.
Closet / Pan may not be Levelled.
Should be done by proper levelling.