Fire Resistant Cables PV-1X4mm2 High Standard Description:
A. Application:Double insulation,electron-beam cross linked cables for photovotaic power station.
Construction:Tinned copper,according toVDE0295/IEC60228,Class5
B. Material Properties/Standards:
1.Fire-resistant performance:IEC60332-1.
2.Smoke emission:IEC61034;EN50268-2
3.Low fire load:DIN51900
4.Approvals:TUV2PfG 1169/08.2007 PV1-F.
5. Application Standards:UNE211 23;UNE20.460-5-52, UTE C 32-502
Fire Resistant Cables PV-1X4mm2 High Standard Technical Data:
1.Nominal Voltage:U0/U=600/1000V AC, 1000/1800V DC ;
2.Test Voltage:6500V,50Hz,5Min.
3.Temperature Rating:45oC upto+125oC, -40oF upto+257oF, Ambient temperature:25years(TUV) -40oC upto+90oC, -40oF upto+194oF, Max.Short circuit temperature:280oC, +536oF.
5.Bending Radius:Fixed installation>4X Occasionally moved>5X
Fire Resistant Cables PV-1X4mm2 High Standard Specification:
Construction | Conductor construction. | Conductor | Outer | Resistance Max. | Current Carring Capacity | ||||
nxmm2 | n/m | mm | mm | Ω/Km | A | ||||
1X1.5 | 30/0.25 | 1.58 | 4.90 | 13.30 | 30 | ||||
1x2.5 | 50/0.25 | 2.02 | 5.45 | 7.98 | 41 | ||||
1x4 | 56/0.3 | 2.30 | 6.10 | 4.75 | 55 | ||||
1x6 | 84/0.3 | 3.42 | 7.20 | 3.39 | 70 | ||||
1x10.0 | 142/0.3 | 4.56 | 9.00 | 1.95 | 98 | ||||
1x16.0 | 228/0.3 | 5.60 | 10.20 | 1.24 | 132 | ||||
1x25.0 | 361/0.3 | 6.95 | 12.00 | 0.795 | 176 | ||||
1x35.0 | 525/0.3 | 8.74 | 13.80 | 0.565 | 218 | ||||
1x50.0 | 720/0.3 | 9.20 | 14.80 | 0.393 | 280 | ||||
1x70.0 | 988/0.3 | 11.00 | 16.90 | 0.277 | 350 | ||||
1x95.0 | 1349/0.3 | 12.50 | 18.70 | 0.21 | 410 | ||||
1x120.0 | 1691/0.3 | 14.20 | 20.70 | 0.164 | 480 |