TECHNICAL DATA
|
|
|
|
|
||||
ITEM
|
|
SPECIFICATIONS
|
|
|
||||
Main Input
|
Rated voltage and frequency
|
1 phase 200V class: 200V-240V, 50Hz/60Hz
|
|
|
||||
|
|
3 phase 400V class: 380V-480V, 50Hz/60Hz
|
|
|
||||
|
Allowable value of change
|
Voltage: 220V-15% ~ 240V+10%; Frequency: ±5% Voltage: 380V-15% ~ 480V+10%; Frequency: ±5%
|
|
|
||||
Main output
|
Output voltage
|
Maximum output voltage equals to input voltage
|
|
|
||||
|
Output frequency
|
0.5 Hz to 400 Hz
|
|
|
||||
|
Overload capacity
|
150% of rated output current for 60s 200% of rated output current for 2s
|
|
|
||||
Control performance
|
|
V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving
|
|
|
||||
|
Setting method of run command
|
Outer terminal, keyboard panel, serial communication
|
|
|
||||
|
Setting method of speed command
|
Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal
|
|
|
||||
|
Speed setting resolution
|
Keyboard: 0.1 Hz Analog setting: 0.05/50Hz (10bit)
|
|
|
||||
|
Speed control precision
|
V/f control: ±2% vector control without PG (open loop control): ±0.2%
|
|
|
||||
|
Speed control range
|
V/f control 1:40 vector control without PG (open loop control) 1:200
|
|
|
||||
|
Acceleration and Deceleration Time
|
0-3200.0s
|
|
|
||||
|
Switching frequency
|
1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency
|
|
|
||||
|
Serial Communication
|
2-way RS-485, MODBUS-RTU, RJ45 connection port
|
|
|
||||
Environment
|
Ingress protection
|
IP20
|
|
|
||||
|
Working temperature
|
-10~50℃
|
|
|
||||
|
Storage temperature
|
-20~60℃
|
|
|
||||
|
Humidity
|
No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3
|
|
|
||||
|
Altitude
|
1000m or below (Derating is necessary when the altitude is higher than 1000m)
|
|
|
||||
|
Cooling method
|
Fan
|
|
|
||||
|
Installation place
|
Room
|
|
|
||||
FOR MORE INFORMATION, PLS CONTACT THE CUSTOMER SERVICE.
|
|
|
|
|